BTTW/YTTW, Fire Resistant Cable, 0.6/1 kv, Multi-Core Inorganic Mineral Insulated Corrugated Copper Sheathed Cable
USD $5 - $60 /Meter
Min.Order:500 Meters
Fire Resistant Cable 0.6/1Kv 1/C Inorganic Mineral Insulated Corrugated Copper Sheathed Cable
PVC Sdi Cable, 450/750 V, 1/C, Australian Cu/V-90/PVC Power Cable (AS/NZS 5000.2)
Cu/XLPE/PVC, Low Voltage Power Cable, 0.6/1 kV (IEC 60502-1)
YAKXS, Low Voltage Power Cable, 0.6/1 kv, Al/XLPE/PVC (IEC 60502-1/HD 603)
NAY2Y, Low Voltage Power Cable, 0.6/1 kv, Al/XLPE/HDPE (DIN VDE 0276-603/HD 603)
BTTW/YTTW Metal Sheathed Inorganic Mineral Insulated Cable
Product Details
BTTW/YTTW Metal Sheathed Inorganic Mineral Insulated Cable
Flexible fireproof cable and copper sheath embossing mineral insulated cable. The cable is a new fireproof cable defects based on modified insulated cables in mineral, it can overcome the disadvantages of mineral insulated cable production is limited by the length of the middle joint installation, avoid appearing in question, has the advantages of the insulation layer is not easy to damp, installation convenience, with the continuous promotion of the product excellent performance, they are increasingly affected by the broad masses of customers, it has been widely used in industrial and civil construction.
Properties
Fireproof performance, fire resistance rating will not only meet the national standard GB12666.6A 950 degree Celsius, 90min, but also to meet the provisions of the United Kingdom BS6387-1994 A Grade of 650 degree Celsius 3H; B 750 degree Celsius 3H; C 950 degree Celsius 3H requirements; At the same time, in the combustion can tolerance water spray and mechanical impact; 2, continuous length, whether it is single core, or multi-core cable, its length can satisfy the power supply need of length, above each continuous lengths up to 1000m; 3, section of a large, single core cable section is 630mm2, multicore cables up to 70mm2; 4, with flexible, cable disc in the disc, the bending radius is 6-10D; 5, burning smoke-free non-toxic using inorganic materials, insulation, does not produce any harmful gas during burning, no 2 pollution, is the real green environmental protection products; 6, the overload capacity is large, the cable ampacity not only large, but also has large overload capacity. According to the wiring to be shown, usually cable surface temperature ≤ 70 degree Celsius, if the wiring can not touch, nor with the combustible materials in contact, cable sheathing temperature up to 105 degree Celsius. Overload fireproof cable long-term working temperature can reach 250 degree Celsius 7, corrosion resistance, good shielding property, the copper sheath good corrosion resistance, in particular or corrosion of the copper environment, should be applied a layer of low smoke zero halogen or plastic external protecting layer on the copper sheath. In the shielded copper sheath, no electromagnetic interference, have not the signal, control cable transmission information interference 8, good safety, fire cable to normal power supply in the flame (normal power supply 950 degree Celsius for more than 3 hours), starting a fire extinguisher, reducing fire loss. The copper sheath is a good conductor, grounding is best, greatly improve the sensitivity and reliability of grounding protection 9, long service life, high temperature is not easy to aging, in the normal condition, its service life is more than 100 years. 10, flexible fire-proof cable transportation, installation, assembly is simple, similar to that of an ordinary cable, 11, economical, flexible fire-proof cable because of advanced technology, simple installation, low in the same conditions the comprehensive cost than mineral insulated cable charges.
Application
Shopping mall, department store, hospital, school, stadium, exhibition center, train station, airport, subway, commercial buildings, hotels, places with dense population, iron and steel enterprises, 100 meters above the building.
Two Core | ||||
Conductor Cross-section | Copper Sheath Corss-section | Insulation Thickness | Approx. Outer Diameter | Conductor Resistance |
mm2 | mm2 | mm | mm | Ω/km |
2x2.5 | 10 | 0.8 | 8 | 7.41 |
2x4 | 15 | 0.8 | 9.3 | 4.61 |
2x6 | 17 | 0.8 | 10.7 | 3.08 |
2x10 | 39 | 1 | 14.2 | 1.83 |
2x16 | 45 | 1 | 16.8 | 1.5 |
2x25 | 54 | 1 | 19.3 | 0.727 |
2x35 | 67 | 1.1 | 21.55 | 0.524 |
2x50 | 82 | 1.2 | 19.7 | 0.387 |
2x70 | 96 | 1.2 | 21.9 | 0.268 |
2x95 | 110 | 1.2 | 24.1 | 0.193 |
2x120 | 126 | 1.2 | 25 | 0.153 |
Three Core | ||||
Conductor Cross-section | Copper Sheath Corss-section | Insulation Thickness | Approx. Outer Diameter | Conductor Resistance |
mm2 | mm2 | mm | mm | Ω/km |
3x2.5 | 13.6 | 0.8 | 8.8 | 7.41 |
3x4 | 15.4 | 0.8 | 10.2 | 4.61 |
3x6 | 17.4 | 0.8 | 11.3 | 3.08 |
3x10 | 27.7 | 1 | 14.8 | 1.83 |
3x16 | 32.3 | 1 | 17.7 | 1.5 |
3x25 | 44.3 | 1 | 20.4 | 0.727 |
3x35 | 57.8 | 1.1 | 22.7 | 0.524 |
3x50 | 66.2 | 1.2 | 22.8 | 0.387 |
3x70 | 85.8 | 1.2 | 25.6 | 0.268 |
3x95 | 98.1 | 1.2 | 28.5 | 0.193 |
3x120 | 108.7 | 1.2 | 31.3 | 0.153 |
3+1 Core | ||||
Conductor Cross-section | Copper Sheath Corss-section | Insulation Thickness | Approx. Outer Diameter | Conductor Resistance |
mm2 | mm2 | mm | mm | Ω/km |
3x16+1x10 | 41.6 | 1 | 18.8 | 1.665 |
3x25+1x16 | 55.9 | 1 | 21.6 | 1.1135 |
3x35+1x16 | 69.6 | 1.1 | 23.7 | 1.012 |
3x50+1x25 | 81.2 | 1.2 | 24.3 | 1.557 |
3x70+1x35 | 93.6 | 1.2 | 28.2 | 0.396 |
3x95+1x50 | 106.4 | 1.2 | 32.8 | 0.29 |
3x120+1x70 | 132.2 | 1.2 | 37.2 | 0.2105 |
Four Core | ||||
Conductor Cross-section | Copper Sheath Corss-section | Insulation Thickness | Approx. Outer Diameter | Conductor Resistance |
mm2 | mm2 | mm | mm | Ω/km |
4x6 | 20 | 0.8 | 12.6 | 3.08 |
4x10 | 31.9 | 1 | 16.9 | 1.83 |
4x16 | 43.2 | 1 | 19.2 | 1.5 |
4x25 | 58.1 | 1 | 22.2 | 0.727 |
4x35 | 74.9 | 1.1 | 24.9 | 0.524 |
4x50 | 85.8 | 1.2 | 25 | 0.387 |
4x70 | 99.5 | 1.2 | 28.2 | 0.268 |
4x95 | 113.9 | 1.2 | 32.2 | 0.193 |
4x120 | 139.6 | 1.2 | 35 | 0.153 |