DLO, Diesel Locomotive Cable, 2 kv, 1/C, Cu/EPR/CPE (ICEA S-95-658/NEMA WC70/UL 44/CSA C22.2 No. 38) Quality Choice
USD $2 - $35 /Meter
Min.Order:500 Meters
Dlo Cable Extreme Torsion 600-2000 V 1/C Cu/Epr/CPE ICEA S-95-658/NEMA WC70/UL
YJLW02, EHV Power Cable, 48/66 kV~127/220 kV, Cu/XLPE/Corrugated AL/PVC (GB/T 11017/IEC 60840)
H03VV-F, House Wiring, Electric Wire, 300/500 V, Flexible Cu/PVC/PVC (HD 21.5/VDE 0482-332)
2192-Y, Electric Wire, 300/500 V, Flexible Cu/PVC/PVC Cable (BS 6500)
H05V-K, House Wiring, Electric Wire, 300/500 V, Class 5 Cu/PVC (HD 21.3)
DLO, Diesel Locomotive Cable, 2 KV, 1/C, Cu/EPR/CPE (ICEA S-95-658/NEMA WC70/UL 44/CSA C22.2 No. 38)
Features
Cable is Listed RHH/RHW-2 per UL, and Listed RW90/R90 per CSA. Jacket is rated Oil Resistance I or II rated per UL 44. All sizes meet VW-1 flame test. Type RHH/RHW-2 is rated Sun Resistance For CT use, 1/0 AWG and larger. Type RW90/R90 is rated -40 °C and FT4. Meets vertical flame tests.
Application
As power cable used in DLO Locomotive Cable, railroad and transit car wiring where high reliability is required. Also suitable for use in static and dynamic wind power applications. For portable and fixed installations leads for motors, generators, batteries.
Standards
UL 44
Rubber Insulated Wires and Cables.
CSA C22.2 No. 38
Thermoset Insulated Wires and Cables.
ICEA S-95-658/NEMA WC70
Nonshielded 0 - 2000 V Cables.
Specifications
Maximum operating voltage: 2000 volts
Maximum conductor operation temperatures: 90 °C wet and dry locations
Engineering Information
1. Conductor: Soft annealed tinned coated copper conductor, flexible stranding per AAR RP-588, and ASTM B3, B172, B174 as applicable. On request, uncoated copper wires.
Sizes: 14 AWG - 1111 kcmil.
2. Separator: A suitable opaque tape, as required.
3. Insulation: Flame retardant thermoset ethylene propylene rubber (EPR), meeting the requirements of UL 44.
4. Jacket: Black flame retardant thermoset chlorinated polyethylene (CPE) jacket, meeting the
requirements of UL 44.
Conductor Size | Number of Strands | Size of Each Strand | Insulation Thickness | Jacket Thickness | Maximum Overall Diameter | Approximate Total Weight |
AWG or kcmil | AWG | mil | mil | in | lb/kft | |
14 | 19 | 27 | 45 | 25 | 0.22 | 33.00 |
12 | 19 | 25 | 45 | 30 | 0.25 | 46.00 |
10 | 27 | 24 | 45 | 30.00 | 0.28 | 65.00 |
8 | 37 | 24 | 60 | 30 | 0.33 | 91.00 |
6 | 63 | 24 | 60 | 30 | 0.39 | 136.00 |
4 | 105 | 24 | 60 | 30 | 0.45 | 201.00 |
2 | 154 | 24 | 60 | 30 | 0.51 | 274.00 |
1 | 224 | 24 | 80 | 45 | 0.65 | 419.00 |
1/0 | 273 | 24 | 80 | 45 | 0.69 | 492.00 |
2/0 | 323 | 24 | 80 | 45 | 0.74 | 575.00 |
3/0 | 426 | 24 | 80 | 45 | 0.83 | 770.00 |
4/0 | 551 | 24 | 80 | 45 | 0.89 | 884.00 |
263 | 646 | 24 | 95 | 65 | 1.01 | 1114.00 |
313 | 779 | 24 | 95 | 65 | 1.08 | 1309.00 |
374 | 931 | 24 | 95 | 65 | 1.14 | 1528.00 |
444 | 1110 | 24 | 95 | 65 | 1.22 | 1785.00 |
535 | 1332 | 24 | 110 | 65 | 1.33 | 2140.00 |
646 | 1591 | 24 | 110 | 65 | 1.42 | 2546.00 |
778 | 1952 | 24 | 110 | 65 | 1.53 | 3017.00 |
929 | 2318 | 24 | 110 | 65 | 1.64 | 3529.00 |
1111 | 2745 | 24 | 125 | 95 | 1.85 | 4291.00 |