All-In-One Heat Pump_High Efficient Heat Pump)
USD $500.89 - $1,000.65 /Set
Min.Order:1 Set
Heat Pump-Unique Energy Saving, Energy From Nature
The attraction and beauty of the heat pump water heating technology is that the amount of electrical energy needed to make hot water is greatly reduced compared to a conventional electric water heater. The GMO heat pump water heater consume only 1kWh of electricity to generate the heat energy equivalent of 2-6kWh. The efficiency of the heat pump rises with increasing ambient air temperatures. The unique GMO heat pump technology is a radical innovation in the water heater industry.
In a warm climate, the heat pump can either be placed in the garage where it takes heat from the ambient air, or inside the house, where it helps cool the room. In a cooler climate, the heat pump typically placed in the basement where it also acts as a dehumidifier when creating hot water.
When the ambient temperature low than 5 °C,or the heat pump setting temperature higher than 80 °C,then an electric backup element with 1.5kW loading will automatically activate.
Benefits
General Date | ||
Model | KD50W-A-134-150 | KD50W-A-134-200 |
Capacity L | 150 | 200 |
Operating temperature range °C | -7 to 43 | -7 to 43 |
DHW temperature °C | 60 | 60 |
Air flow rate CFM | 900 | 900 |
Sound level at 1.1yards/1m dB | 55 | 55 |
Refrigerant filling weight g | R 134a / 900 | R 134a / 900 |
Compressor Type | Rotary | Rotary |
Height mm | 1680 | 2000 |
Diameter mm | 540 | 540 |
Weight kg | 87 | 100 |
Package Size | 630*630*1690 | 630*630*2010 |
Water connection | G3/4” | G3/4” |
Condensate Connection | ¾” | ¾” |
Condenser | Safety copper heat exchanger(tank wrap-around condenser) | Safety copper heat exchanger(tank wrap-around condenser) |
Maximum Operating pressure, water side Mpa | 0.8 | 0.8 |
Maximum exhaust/inhaling operating pressure,refrigerant side Mpa | 2.3Mpa/0.38Mpa | 2.3Mpa/0.38Mpa |
P/T Relief Valve | 99°C/1Mpa | 99°C/1Mpa |
Electrical Data | ||
Voltage/Frequency V/Hz | Single Phase 220-240/50 | Single Phase 220-240/50 |
Rated Power W | 530 | 530 |
Maximum power consumption W | 650 | 650 |
Nominal heat capacity W | 2100 | 2100 |
Rated current compressor & fan A | 2.5 | 2.5 |
Circuit breaker A | 16 | 16 |
Rated power, booster heater W | 1500 | 1500 |
COP(ambient temperature20°C) | 3.8 | 3.8 |
Typical COP range | 2-6 | 2-6 |
Average hot water yield L/H | 50 | 50 |
Grade of electric shock resistance | ⅠGrade | ⅠGrade |
Heat Pump Container Loading Information
Heat Pump Type | 20'GP | 40'HQ |
150L | 27 Sets | 54 Sets |
200L | 27 Sets | 54 Sets |
Heat Pump Pictures
Need More Heat Pump Info, please feel free to contract us
Skype: solarsystem88
Heat Pump | Heat Pump | Heat Pump |