RETRACTABLE SOOT BLOWER FOR BOILER
USD $100 - $10,000 /Set
Min.Order:1 Set
Qingdao Xingfu Boiler Thermoelectric Devices Co., Ltd.
Rotary Soot Blower
Model: XF/DSB60-T
Name: Fixed rotary sootblowers
Uses:
For mounting on the tail of the economizer and air preheater flue.
Structural features:
Compact, do not need to install the platform; easy maintenance; regional comprehensive purge.
Technical Specifications:
Purge stroke: 0 ~ 360 º
Sootblowing pressure: 0.8 ~ 1.2Mpa
Soot blowing medium: steam or compressed air
Medium temperature: t <500 °C
Media consumption: 30 ~ 100Kg/min
Purge stroke: T =6m
Purge radius: 0.5 ~ 2.5M
Purge angle: 0 ~ 360º
Rotation speed: 5.4rpm
Motor power: 0.37KW
Motor power supply: 380V 50Hz
Retractable Soot Blower
Caption:
XF/LSB-11/T soot blowers
The standard design products using advanced foreign technology, manufacturing, mainly arranged in the boiler economizer tube to the heater and other parts, and some small boilers convection tubes.The flue gas temperature of the work area does not exceed 500 ° C, soot blower tube nozzle tube and outer tube, half extends into the furnace flue gas channel is disabled, the nozzle tube equipped with a multiple venturi nozzle. Purge nozzle the spiral telescopic movement, for a thorough purging of different nozzles for different regions.
Name: semi-retractable soot blower
Uses:
Mainly used for cleaning boilers screen and control of heating surface, such as: economizer, tail flue heating surface.
Main features:
Using toothed rack engaging the drive to the soot-blowing tube rearward movement, and easy to maintain; hanging front and rear ends, to accommodate the expansion of the horizontal and vertical directions of the boiler furnace wall; motor gear box, with a filler walking tank using split, improve the drive reliability gearbox oil leakage problems and solved; half of the soot-blowing tube is placed inside the furnace and the other half is placed outside of the furnace, can be greatly reduced the boiler installation platform and purge time, thereby reducing the steam consumption.
Technical Specifications:
Purge stroke: | T<6 m T =6 m |
Sootblowing pressure: | 0.8 ~ 1.2Mpa |
Sootblowing media: | Steam or compressed air |
Medium temperature: | t <500 º |
Media consumption: | 30 ~ 60Kg/min |
Purge radius: | 0.5 ~ 4.0m |
Purge angle: | 0 ~ 360 º |
Motor power: | 0.55KW 1400rpm |
Motor power: | 380V 50Hz |
|
|