Natural gas hot water boiler with 91% thermal efficiency
USD $10,000 - $90,000 /Set
Min.Order:1 Set
Qingdao Xingfu Boiler Thermoelectric Devices Co., Ltd.
Product Features
1. Automatic operation, safety, and reliability shall characterize the boiler provided with various control, protection device, and automatic control of steam pressure, water level and combustion system. The hot water boiler shall use programe control, and temperature and time control featuring the following advantages: easy to use, simple to maintain, as well as saving the manpower and material resources.
2. Abundantly, obvious effect of energy-saving, and meeting the environmental requirements.
3. The application of totally enclosed combustion shall make the boiler room to be tasteless, noiseless, unpolluted, beautifull, and clean.
4. Compact structure, small floor area, and simple installation shall characterize the boiler.
WNS Series Diesel Hot Water Boiler | ||||||||||||
Boiler Type
Item | WNS 0.350.7/ 95/70-Y(Q) | WNS 0.70.7/ 95/70-Y(Q) | WNS 1.4-0.7/ 115/70-Y(Q) | WNS 2.1-1.0/ 115/70-Y(Q) | WNS 2.8-1.0/ 115/70-Y(Q) | WNS 4.2-1.0/ 115/70-Y(Q) | WNS 5.6-1.0/ 115/70-Y(Q) | WNS 7.0-1.0/ 115/70-Y(Q) | WNS 10.5-1.25/ 130/70-Y(Q) | WNS 14-1.25/ 130/70-Y(Q) | ||
Rated Thermal Power | Mw | 0.35 | 0.7 | 1.4 | 2.1 | 2.8 | 4.2 | 5.6 | 7.0 | 10.5 | 14.0 | |
Working Pressure | Mpa | 0.7 | 0.7 | 0.7 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 | 1.25 | 1.25 | |
Outlet Water Temperature | ℃ | 95 | 95 | 115 | 115 | 115 | 115 | 115 | 115 | 130 | 130 | |
Return Water Temperature | ℃ | 70 | ||||||||||
Thermal Efficiency | % | 89 | 90 | 90 | 90 | 91 | 91 | 91 | 91 | 91 | 91 | |
Heating Space | M³ | 3000 | 6000 | 12000 | 18000 | 24000 | 36000 | 48000 | 60000 | 90000 | 120000 | |
Power Distribution | Kw | 0.55 | 1.1 | 2.2 | 7.5 | 7.5 | 12 | 37 | 37 | 75 | 110 | |
Water Capacity | T | 0.64 | 1.6 | 2.3 | 3.6 | 4.9 | 70 | 10.5 | 12.98 | 13.8 | 14.6 | |
Fuel Consumption | Light Oil | Kg/h | 33 | 66 | 131 | 208 | 287 | 385 | 522 | 652 | 989 | 1318 |
Mazout | Kg/h | 33.3 | 67 | 135 | 213 | 292 | 410 | 532 | 665 | 1002 | 1336 | |
Coal Gas | Nm³/h | 77.3 | 155 | 314 | 460 | 630 | 946 | 1237 | 1546 | 2288 | 3050 | |
Natural Gas | Nm³/h | 43 | 85 | 169 | 251 | 334 | 485 | 619 | 773 | 1043 | 1390 | |
Inlet&Outlet Water Valve Diameter | Mm | DN80 | DN100 | DN100 | DN125 | DN125 | DN150 | DN200 | DN200 | DN200 | DN200 | |
Chimney Diameter | Mm | 200 | 300 | 350 | 450 | 500 | 600 | 700 | 800 | 1000 | 1200 | |
Maximum Transportation Size | L | Mm | 3200 | 3700 | 3800 | 4700 | 5300 | 5400 | 5600 | 6020 | 8300 | 9000 |
W | Mm | 1700 | 1800 | 2500 | 2600 | 2700 | 2900 | 2900 | 3300 | 3300 | 3800 | |
H | Mm | 1600 | 1800 | 2100 | 2100 | 2400 | 2500 | 3000 | 3100 | 3400 | 3800 | |
Maximum Transportation Weight | T | 1.5 | 3.8 | 5.2 | 5.9 | 9.6 | 14 | 17.2 | 21 | 30.8 | 36 |