Coal conducting oil boiler
USD $10,000 - $600,000 /Set
Min.Order:1 Set
Qingdao Xingfu Boiler Thermoelectric Devices Co., Ltd.
Coal conducting oil boiler
Coal thermal oil boiler
1. Higher working temperature shall be obtained under lower operating pressure.
2. Steady heating and accurate temperature adjustment shall be performed.
3. Under each grade loading, the thermal efficiency shall remain in a high level.
4. The boiler shall save power, water, as well as investment.
Item/Parameter/Model | YGL0.4-0.7-AII | YGL0.63-0.7 -AII | YLL0.8-0.7 -AII | YLL1.0-0.7-AII | YLL1.25-0.7 -AII | YLL1.6-0.7 -AII | YLL2.0-0.7 -AII | YLL2.5-0.7 -AII | YLL3.15-0.7 -AII | YLL4.0-0.7 -AII | |
Rated thermal power | MW | 0.4 | 0.63 | 0.8 | 1.0 | 1.25 | 1.6 | 2.0 | 2.5 | 3.15 | 4.0 |
Kcal | 30x104 | 40x104 | 60x104 | 80x104 | 100x104 | 120x104 | 160x104 | 200x104 | 240x104 | 300x104 | |
Rated operation pressure | Mpa | 0.7 |
|
| |||||||
C | 350 | 270 | 270 | 260 | 260 | 260 | 260 | 260 | 260 | 260 | |
Medium of Passing heat | Thermal oil | ||||||||||
Thermal efficiency | % | >62 | >62 | >72 | >72 | >72 | >72 | >72 | >72 | >72 | >72 |
Oil capacity | m3 | 0.48 | 0.66 | 1.08 | 1.63 | 1.78 | 1.98 | 2.9 | 3.52 | 4.47 | 6.15 |
Circulation oil volume | m3/h | 25.4 | 26.9 | 38 | 50 | 65.4 | 79 | 100 | 124 | 150 | 191 |
Diameter of pipe | mm | DN65 | DN70 | DN80 | DN100 | DN100 | DN125 | DN150 | DN150 | DN150 | DN200 |
Dimensions of boiler M | L | 1.67 | 1.75 | 4.67 | 4.67 | 4.87 | 4.87 | 5.25 | 5.25 | 5.25 | 6.2 |
W |
|
| 1.92 | 1.92 | 2.33 | 2.33 | 2.75 | 2.79 | 3.04 | 3.25 | |
H | 3.36 | 3.67 | 4.22 | 4.7 | 4.73 | 5.14 | 5.87 | 6.33 | 7.27 | 7.82 | |
Rated exit temperature | C | 260 | |||||||||
Rated entrance temperature | C | 225 | |||||||||
Coal consumption | Kg/h | 72 | 95 | 148 | 198 | 260 | 295 | 390 | 520 | 624 | 780 |
Total weight | T | 6 | 6.5 | 20 | 23 | 25 | 29 | 30 | 33 | 37 | 45 |
Specifications/Model | YLW -1400MA | YLW -1800MA | YLW -2500MA | YLW -3000MA | YLW -3500MA | YLW -4200MA | YLW -5600MA | YLW -7000MA | YLW -8200MA | YLW -9300MA | |
Thermal Power-Kcal/h104 | KW | 1400 | 1800 | 2500 | 3000 | 3500 | 4200 | 5600 | 7000 | 8200 | 9300 |
104 | 120 | 150 | 200 | 250 | 300 | 360 | 480 | 600 | 700 | 800 | |
Rated pressure | Mpa | 1.0 | |||||||||
Outlet temperaure | C | 320 | |||||||||
Inlet temperature | C | 290 | |||||||||
Heating area | M2 | 130 | 157 | 168.7 | 192.2 | 263.8 | 298 | 490.3 | 574.5 | 634.2 | 723.4 |
Medium | Thermal oil | ||||||||||
Fuel | II,III Bitumite | ||||||||||
Coal consumption | Kg/h | 290 | 496 | 620 | 797 | 895 | 996 | 1248 | 1495 | 1744 | 1993 |
Oil capacity | M3 | 2.47 | 2.73 | 2.96 | 3.17 | 3.24 | 3.46 | 5.38 | 6.30 | 8.03 | 9.31 |
Circulating oil | M3/h | 120 | 130 | 143.3 | 172 | 187 | 200 | 233.5 | 272.4 | 403.7 | 457.8 |
Design efficiency | % | 73 | 73 | 73 | 73 | 73 | 73 | 73 | 73 | 73.5 | 76.7 |
Total power | Kw | 79.9 | 87.65 | 87.65 | 104.65 | 104.65 | 104.65 | 144.1 | 144.1 | 201.2 | 287.5 |
Pipe diameter | DN | 150 | 150 | 150 | 150 | 150 | 150 | 200 | 200 | 300 | 300 |
Max weight | kg | 17450 | 18650 | 19579 | 20492 | 22730 | 24660 | 26149 | 28309 | 32425 | 34782 |
Dimension(mm) | L | 4960 | 4960 | 5207 | 5207 | 6432 | 6432 | 7866 | 7866 | 8086 | 9669 |
W | 2519 | 2519 | 2519 | 2519 | 2700 | 2700 | 3513 | 3513 | 3460 | 3460 | |
H | 2656 | 3280 | 3388 | 4100 | 4365 | 4810 | 3314 | 3500 | 3671 | 3671 |
Notes:
The coal consumption at full load operation shall be calculated as II bituminous coal (dw=21320KJ/KG)
If the product capability parameter noted is changed,you shall refer to the technical documents on delivery.