AC100-240V Wireless RGBW led stage lighting

AC100-240V Wireless RGBW led stage lighting

Negotiable /Piece

Min.Order:10 Pieces

Supply Ability:
5000 Piece / Pieces per Month
Port:
shenzhen
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Install Style:
Free Standing
Lamp Power(W):
147
Lamp Luminous Flux(lm):
3000
Lamp Luminous Efficiency(lm/w):
90
Color Temperature(CCT):
Other, RGBW
Working Lifetime(Hour):
50000

Shenzhen Enrich Lighting Co., Ltd.

Business Type: Manufacturer,Trading Company,Distributor/Wholesaler
Shenzhen Guangdong China
Main Products: LED Neon Light ,LED T8 Tube Light ,LED Spotlight ,LED demo case ,LED spot light

Product Details

Specifications

stage Lighting
1. 54pcs x 3w led
2. IP66
3. AC100~240V 50/60Hz

 

stage lighting ; led stage light ; wedding stage decoration ; stage decoration for christmas ; christmas stage decoration ; led stage curtain screen ; stage decoration ;wedding stage light

 

DMX led Stage lighting

 

1. Working Voltage: AC100-240V / 50-60Hz

2. Light source: 3W LED x 54pcs

3. Dimensions:30cm X 23cm X 34cm

4. DMX Channels: 4/5/7Channels

5. LED Qty: RGBW (R14,G14G14,W12)

6. 25degree

7. Max Power: 147w

8. 9.2kg

 

AC100-240V Wireless RGBW led stage lighting

AC100-240V Wireless RGBW led stage lighting

 

1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable.

2. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last unit.

3. Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the input of the next unit. The cable can not branched or split to a `Y` cable. DMX 512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system.

4. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one of the units’ power is disconnected.

5. Each lighting unit needs to have an address set to receive the data sent by the controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).

6. The end of the DMX 512 system should be terminated to reduce signal errors.

7. 3 pin XLR connectors are more popular than 5 pin XLR.

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin 4/Pin 5: Not used.

 

How To Control The Unit

 

You can operate the unit in two ways:

1. By master/slave built-in preprogram function

2. By DMX controller No need to turn the unit off when you change the DMX address, as new DMX address setting will be effected at once. Every time you turn the unit on, it will show on the display and move all the motors to their ‘home’ position. After that the unit will be ready to receive DMX signal or run the built in programs.

 

Master/Slave Built In Preprogrammed Function

By linking the units in master/slave connection, the first unit will control the other units to give an automatic, sound activated, synchronized light show. This function is good when you want an instant show. You have to select (show 1) or (show 2) ……or (show 19, show17~19 have to be edited by the user) show for the first unit. Its DMX input jack will have nothing plugged into. The other units will be slave mode automatically.

 

DMX Controller

Use universal DMX controller to control the units, you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal. Press the MENU button up to when the is showing on the display. Press ENTER button and the display will blink. Use DOWN and UP button to change the DMX512 address. Once the address has been selected, press and keep ENTER button pressed up to when the display stops blinking or storing automatically 8 seconds later. To go back to the functions without any change press the MENU button again.

 

Control Panel

AC100-240V Wireless RGBW led stage lighting

1: Power Water proof connectors for power input/output

2: DMX input/output Water proof connectors for DMX 512 operation, 3-pin XLR cable to link the units together

3: Display To show the menu and the selected functions

4. MENU: To select the programming functions

5. DOWN: To go backward in the selected functions

6. UP: To go forward in the selected functions

7. ENTER: To confirm the selected functions

 

 

Installation

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it.

 

AC100-240V Wireless RGBW led stage lighting

 

Contact Supplier

Ms. Joan Chow Sales Manager Chat Now
Telephone
0086-755-83259929
Fax
0086-755-23570706
Address
23Floor, Block B, Chinto Technology Blvd, Minzhi Road, Longhua New District, Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Lights & Lighting > Professional Lighting > Stage Lights > Follow Spot Lights
Categories
Hi~