Standard with Fetal irritability, contractions and fetal heart, SM-110 Plus add blood oxygen, pulse rate and blood pressure. SM-110T Fetal Monitor for twins. Description: Unicare MCF-21K are high-tech fetal& maternal monitor, it offers a reliable, high-performance solution for fetal monitoring needs in doctors’ practices, clinics and hospitals, from pre-natal check-ups to antepartum monitoring of high-risk pregnancies Feature: -Standard configuration: FHR, TOCO,FM , AFM, FMP -Folded 10.1 inch TFT LCD high-brightness screen -12 elements water proof pulse doppler transducer -Event marker for easy documentation of events and kick counts -Fetal movement profile ( FMP) detects and automatically records gross fetal body movements -Twin fetus monitoring capabilityand twin signal overlap alarm function -Configuration audible and flashing alarms -Built-in high speed thermal printer ( width: 112mm) -Supporting TCP/IP or wireless connection to the central monitoring station -Internal Li-ion battery power AC power from external power supply Specifications: Physical Specifications | Dimension Weight | Dimension | 32cm (W)*26cm (D)*9cm (H) | Weight | standard configuration: 2.8 kg | Operation Environment | Power requirements | AC100-240V , 50/60Hz | Power | 50VA | Temperature | 5-40°C | Humidity | 30-93% non-condensing | Fetal Performance Specifications | Performance Specifications | Display | 10.1inch (800X600 pixel) color TFT –LCD | Indicator | Visual on-display and integrated, alarm light, audible alarm | Battery | Internal rechargeable Li-ion battery power | Alarm | Visual on-display and integrated, alarm light, audible alarm | Memory | 24-hours memory for fetal traces | Printer | America standard/international standard Built-in thermal printer (112mm) 1/2/3cm/min real-time printing speed, fast print speed (stored traces) | Paper | Z-fold, thermosensitive | Record Message | ID, name, age, date, time, print speed etc | CMS | Support connecting to central monitoring station through LAN (TCP/IP) or wireless connection | Fetal Technical Specifications | Ultrasound (FHR) | Measurement range | US | 50 to 240 bpm | Resolution | Display | 1bpm | Printer | 1bpm | jitter@200 bpm | ≤3bpm | Display update rate | 0.25second | Beat to bea change(max.) for ultrasound | 28bpm | US frequency | 1MHz±5%Hz | TOCO | Measurement method | Strain gauge sensor element | Sensitivity | 1 unit =2.5g | Resolution | 1 unit | Measurement range | 500 units | Baseline setting | 0, 5,10, 15, 20 can be selective | Update rate | 0.25 second | Auto offset correction | 3 second after connecting the transducer | Auto zero adjust | TOCO value is set to zero negative following a negative .Measure value for 5 seconds | Auto Fetal Movement (AFM) | Technique | Pulsed doppler ultrasound | Range | 0-100% | Resolution | 1% | Automatic fetal movement actograph | Manual fetal movement mark | Maternal ECG (MECG) | Heart rate range | 30~300bpm | Resolution | 1bpm | Accuracy | ±1bpm/ ±1% | Leads | I, II, III, avL, avR, avF, V | Sweep speed | 12.5mm/s, 25mm/s, 50mm/s | Gain selection | x 0.25, x0.5 ,x1, x2 | Operation mode | diagnostic, monitor, surgery | Temperature (TEMP) | Technique | Thermistor probe CYSI 400 series compatible | Measurement range | 0°C-50°C | Accuracy | ±0.1°C | | | | | | |
|