HT11 series 6-20 online 1phase UPS

HT11 series 6-20 online 1phase UPS

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
300 Piece / Pieces per Month
Port:
shenzhen
Payment Terms:
T/T L/C

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
INVT
Model Number:
HT1115L
Phase:
Single Phase
Protection:
Short Circuit
Weight:
20KG

INVT Power System (Shenzhen) Co., Ltd.

Business Type: Manufacturer
Shenzhen Guangdong China
Main Products: online ups ,uninterrupted power supply ,200kva online ups ,module ups ,true online ups

Product Details

Specifications

1.single phase UPS, 6~20kVA
2.high input PF(0.99) and output PF(0.9),
3.low THDi, high efficiency
4.big LCD display.

 HT1106SHT1106LHT1110SHT1110LHT1115LHT1120L
INPUT      
Cold StartYES, default frequency=50Hz or settableYES, default frequency=50Hz or settableYES, default frequency=50Hz or settableYES, default frequency=50Hz or settable
Acceptable Input Voltage50%~125%(220VAC/230VAC/240VAC)50%~125%(220VAC/230VAC/240VAC)50%~125%(220VAC/230VAC/240VAC)50%~125%(220VAC/230VAC/240VAC)
 100% load@80%~125%100% load@80%~125%100% load@80%~125%100% load@80%~125%
 90% load@70%~80%90% load@70%~80%90% load@70%~80%90% load@70%~80%
 80% load@60%~70%80% load@60%~70%80% load@60%~70%80% load@60%~70%
 65% load@50%~60%65% load@50%~60%65% load@50%~60%65% load@50%~60%
PhaseSingle phase in,single phase outSingle phase in,single phase outThree phase in,single phase outSingle phase in,single phase out
Transfer Voltage Range     
   -Line low transfer110VAC/115VAC/120VAC110VAC/115VAC/120VAC110VAC/115VAC/120VAC110VAC/115VAC/120VAC
   -Line low recovery116VAC/122VAC/127VAC116VAC/122VAC/127VAC116VAC/122VAC/127VAC116VAC/122VAC/127VAC
   -Line high transfer275VAC/288VAC/300VAC275VAC/288VAC/300VAC275VAC/288VAC/300VAC275VAC/288VAC/300VAC
   -Line high recovery268VAC/279VAC/291VAC268VAC/279VAC/291VAC268VAC/279VAC/291VAC268VAC/279VAC/291VAC
Input Power Factor0.990.990.980.98
Input Frequency Range40Hz - 70Hz40Hz - 70Hz40Hz - 70Hz40Hz - 70Hz
GeneratorSupport Any GeneratorSupport Any GeneratorSupport Any GeneratorSupport Any Generator
OUTPUT     
Frequency adaptableSettableSettableSettableSettable
Power    
   -Power(kVA) max6101520
   -Power(kW) max5.4913.518
Output Voltage    
   -WaveformPure sine wavePure sine wavePure sine wavePure sine wave
   -Nominal voltage220/230/240VAC220/230/240VAC220/230/240VAC220/230/240VAC
   -Voltage regulation± 1 %± 1 %± 1 %± 1 %
   -Transient response 5% (50% - 100% -50%)5% (50% - 100% -50%)5% (50% - 100% -50%)5% (50% - 100% -50%)
   -Transient recovery15ms (0% - 100% -0%)15ms (0% - 100% -0%)15ms(0% - 100% -0%)15ms(0% - 100% -0%)
   -Voltage distortion1% THD, linear load       1% THD, linear load 1% THD, linear load 1% THD, linear load
  5% THD, non-linear load5% THD, non-linear load 5% THD, non-linear load 5% THD, non-linear load
Output Frequency    
   -Synchronization rangesettable,±3Hz defaultsettable,±3Hz defaultsettable,±3Hz defaultsettable,±3Hz default
   -Slew rate0.5~5Hz/s,2 Hz/s default0.5~5Hz/s,2Hz/s default0.5~5Hz/s,2Hz/s default0.5~5Hz/s,2Hz/s default
   -Battery mode(50±0.05) Hz(50±0.05) Hz(50±0.05) Hz(50±0.05) Hz
Transfer Time    
   -Line mode to battery mode0000
   -Inverter to bypass0.1ms000
Efficiency    
   -Line mode with battery full charged93.0%93.0%93.5%93.5%
   -ECO mode98.0%98.0%98.0%98.0%
   -Battery mode92.0%92.0%92.0%92.0%
Noise<48dB@<70%load,<58dB@>70%load;1m away<48dB@<70%load,<60dB@>70%load;1m away53dB@<70%load,<66dB@>70%load;1m away53dB@<70%load,<66dB@>70%load;1m away
Overload Capability (Line Mode)110%: Transfer to bypass after 60 mins.110%: Transfer to bypass after 60 mins110%: Transfer to bypass after 60 mins110%: Transfer to bypass after 60 mins
130%: Transfer to bypass after 1 min130%: Transfer to bypass after 1 min130%: Transfer to bypass after 1 min130%: Transfer to bypass after 1 min
150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode)
Overload Capability (Battery Mode)110%: Shutdown after 10mins (Battery mode)110%: Shutdown after 10mins (Battery mode)110%: Shutdown after 10mins (Battery mode)110%: Shutdown after 10mins (Battery mode)
125%:Shutdown after 10s(Battery mode)125%:Shutdown after 10s(Battery mode)125%:Shutdown after 10s(Battery mode)125%:Shutdown after 10s(Battery mode)
>125%: Shutdown after 1s (Battery mode)>125%: Shutdown after 1s (Battery mode)>125%: Shutdown after 1s (Battery mode)>125%: Shutdown after 1s (Battery mode)
Crest Ratio3:13:13:13:1
BATTERY      
Rating/Type12VDC/7AhDepend on the capacity of external batteries12VDC/9AhDepend on the capacity of external batteriesDepend on the capacity of external batteriesDepend on the capacity of external batteries
Quantity16161616
DC Voltage192VDC192VDC192VDC192VDC
Back-up Time4mins @80% loadDepend on the capacity of external batteries3.5mins @80% loadDepend on the capacity of external batteriesDepend on the capacity of external batteriesDepend on the capacity of external batteries
Battery-Low Voltage(176±3)VDC(176±3)VDC(176±3)VDC(176±3)VDC
Charger      
   -Charging voltage(220±1%)VDC(220±1%)VDC(220±1%)VDC(220±1%)VDC
   -Charging current (max)1A5A1A5A5A5A
   -Charging time7h recharge to 90%Depend on the capacity of external batteries8h recharge to 90%Depend on the capacity of external batteriesDepend on the capacity of external batteriesDepend on the capacity of external batteries
Leakage current<1mA<1mA<1mA<1mA
INDICATOR & ALARM      
DisplayLED+LCDLED+LCDLED+LCDLED+LCD
AlarmSounding once per secondSounding once per secondSounding once per secondSounding once per second
FaultContinuous beepingContinuous beepingContinuous beepingContinuous beeping
INTERFACE      
Smart RS232Standard Cable support INVT Power Monitor SoftwareStandard Cable support INVT Power Monitor SoftwareStandard Cable support INVT Power Monitor SoftwareStandard Cable support INVT Power Monitor Software
Dry Contactor5 Ports5 Ports5 Ports5 Ports
SNMP(option)Power Managment from SNMP Manager and Web BrowserPower Managment from SNMP Manager and Web BrowserPower Managment from SNMP Manager and Web BrowserPower Managment from SNMP Manager and Web Browser
OPTION      
ECO KitYESYESYESYESYESYES
Long Parallel CableYESYESYESYESYESYES
Parallel KitYESYESYESYESYESYES
SNMPYESYESYESYESYESYES

 

Contact Supplier

Ms. Sarah Zhang Manager Chat Now
Telephone
86-755-26782480
Mobile
15220266565
Fax
86-755-26782664
Address
1# Building, Gaofa Industrial Park, Longjing, Nanshan District, Shenzhen, China Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Supplies > Uninterrupted Power Supply (UPS)
Categories