single phase 6kva 6000va stand alone ups power internal battery model
USD $600 - $800 /Unit
Min.Order:1 Unit
INVT Power System (Shenzhen) Co., Ltd.
20kva three phase online ups power supply battery voltage 192vdc
15kva three phase in single phase out online ups power for computer application
10kva 220V/230V/240V three phase in single phase out long back up online ups power
10kva 220V/230V/240V three phase in single phase out online ups power
3kva 3000va 220v 230v 240v long back up online ups power supply
single phase 6kva 6000va stand alone ups power internal battery model
Product Specifications:
HT1106S | HT1106L | HT1110S | HT1110L | |
INPUT | ||||
Cold Start | YES, default frequency=50Hz or settable | YES, default frequency=50Hz or settable | ||
Acceptable Input Voltage | 50%~125%(220VAC/230VAC/240VAC) | 50%~125%(220VAC/230VAC/240VAC) | ||
100% load@80%~125% | 100% load@80%~125% | |||
90% load@70%~80% | 90% load@70%~80% | |||
80% load@60%~70% | 80% load@60%~70% | |||
65% load@50%~60% | 65% load@50%~60% | |||
Phase | Single phase in,single phase out | Single phase in,single phase out | ||
Transfer Voltage Range | ||||
-Line low transfer | 110VAC/115VAC/120VAC | 110VAC/115VAC/120VAC | ||
-Line low recovery | 116VAC/122VAC/127VAC | 116VAC/122VAC/127VAC | ||
-Line high transfer | 275VAC/288VAC/300VAC | 275VAC/288VAC/300VAC | ||
-Line high recovery | 268VAC/279VAC/291VAC | 268VAC/279VAC/291VAC | ||
Input Power Factor | ≥0.99 | ≥0.99 | ||
Input Frequency Range | 40Hz - 70Hz | 40Hz - 70Hz | ||
Generator | Support Any Generator. | Support Any Generator. | ||
OUTPUT | ||||
Frequency adaptable | Settable | Settable | ||
Power | ||||
-Power(kVA) max | 6 | 10 | ||
-Power(kW) max | 5.4 | 9 | ||
Output Voltage | ||||
-Waveform | Pure sine wave | Pure sine wave | ||
-Nominal voltage | 220/230/240VAC | 220/230/240VAC | ||
-Voltage regulation | ± 1 % | ± 1 % | ||
-Transient response | ≤5% (50% - 100% -50%) | ≤5% (50% - 100% -50%) | ||
-Transient recovery | ≤15ms (0% - 100% -0%) | ≤15ms (0% - 100% -0%) | ||
-Voltage distortion | ≤1% THD, linear load | ≤1% THD, linear load | ||
≤ 5% THD, non-linear load | ≤5% THD, non-linear load | |||
Output Frequency | ||||
-Synchronization range | settable,±3Hz default | settable,±3Hz default | ||
-Slew rate | 0.5~5Hz/s,2 Hz/s default | 0.5~5Hz/s,2Hz/s default | ||
-Battery mode | (50±0.05) Hz | (50±0.05) Hz | ||
Transfer Time | ||||
-Line mode to battery mode | 0 | 0 | ||
-Inverter to bypass | 4ms | 0 | ||
Efficiency | ||||
-Line mode with battery full charged | 93.0% | 93.0% | ||
-ECO mode | 98.0% | 98.0% | ||
-Battery mode | 92.0% | 92.0% | ||
Noise | <48dB@<70%load,<58dB@>70%load;1m away | <48dB@<70%load,<60dB@>70%load;1m away | ||
Overload Capability (Line Mode) | 110%: Transfer to bypass after 10 mins. | 110%: Transfer to bypass after 10 mins | ||
130%: Transfer to bypass after 1 min | 130%: Transfer to bypass after 1 min | |||
150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) | 150%: Transfer to bypass after 30s, shutdown after 1 min.(Line mode) | |||
Overload Capability (Battery Mode) | 110%: Shutdown after 10mins (Battery mode) | 110%: Shutdown after 10mins (Battery mode) | ||
125%:Shutdown after 10s(Battery mode) | 125%:Shutdown after 10s(Battery mode) | |||
>125%: Shutdown after 1s (Battery mode) | >125%: Shutdown after 1s (Battery mode) | |||
Crest Ratio | 3:1 | 3:1 | ||
BATTERY | ||||
Rating/Type | 12VDC/7Ah | Depend on the capacity of external batteries | 12VDC/9Ah | Depend on the capacity of external batteries |
Quantity | 16 | 16 | ||
DC Voltage | 192VDC | 192/240VDC | 192VDC | 192/240VDC |
Back-up Time | 4mins @80% load | Depend on the capacity of external batteries | 3.5mins @80% load | Depend on the capacity of external batteries |
Battery-Low Voltage | (176±3)VDC | (176±3)VDC | ||
Charger | ||||
-Charging voltage | (220±1%)VDC | (220±1%)VDC | ||
-Charging current (max) | 1A | 5A | 1A | 5A |
-Charging time | 7h recharge to 90% | Depend on the capacity of external batteries | 8h recharge to 90% | Depend on the capacity of external batteries |
Leakage current | <1mA | <1mA | ||
INDICATOR & ALARM | ||||
Display | LED+LCD | LED+LCD | ||
Alarm | Sounding once per second | |||
Fault | Continuous beeping | |||
INTERFACE | ||||
Smart RS232 | Standard Cable support INVT Power Monitor Software | |||
B type USB(optional) | Standard Cable support INVT Power Monitor Software | |||
EPO | Remoted EPO function for customer. Short to activate | |||
Dry Contactor(optional) | DB9 type and phoenix terminal type for selection. (6 output ports, 1 input port) UPS fault alarm, general alarm, bypass mode, UPS normal mode, battery low voltage alarm, utility failure alarm, remoted shutdown. | |||
SNMP(optional) | Power Managment from SNMP Manager and Web Browser | |||
Option | SNMP, USB, Dry Contactor(AS400),Parallel Kit, ECO Kit, External Battery Cable(standard model), Maintenance Bypass, Maintenance Bypass | |||
Reserved function | Can be designed as deffirent function according to customer's application | |||
MECHANICAL | ||||
W*D*H (mm) | 250*562*650 | 250*504*480 | 250*562*650 | 250*504*480 |
Net Weight (KG) | 57 | 18 | 65 | 20 |
Color | Black | Black |
Product Images:
Our Factory:
Our Exhibitions:
Product Certifications:
Shipping:
FAQ:
Product Quality: We are a public company(stock code: 002334) and owned 800-900 engineers for the control of product quality.
Delivery Time: Usually 15-20days, it depends to your specific order information.
Package: We have professional wooden package for large machine.
Quotation: Please leave your message,and I will send you a formal quotation via email.