Technical specifications | |
Measurement range with corresponding unit: - m/s - °C Calculation of volume of air current: - m³/min (CCM) | 0.2 to 20.0 0.0 to 50.0 (sensor) 0 to 36,000 |
Resolution - Air velocity - Air temperature - Volume of air current (CCM) | 0.1 m/s (for remaining units, up to ft/min = 1.0) 0.1°C 0.001 to 1 m³/min (depending on reading) |
Accuracy - Air velocity - Air temperature - Volume of air current (CCM) | ±1% (of measurement range) or ±5% of the corresponding value ±0.8°C calculated value |
Measuring quota | From 2 sec. to 9 hours |
Internal memory | 16,000 values |
Thermal sensor | - telescopic thermistor/hot wire sensor - contracted length 280 mm - extended length 940 mm - maximum diameter 12 mm - minimum diameter 8 mm (at the leading end) |
Interface | RS-232 |
Software/RS-232 cable | - included, compatible with Windows 95, 98, 2000, XP, for data transfer - data can also be exported to MS Excel |
Display | large 58 x 34 mm LCD |
Operating conditions | device: 0°C to 40°C/<80% r.h. thermal sensor: 0°C to 50°C/<80% r.h. |
Power | 4 batteries (1.5 V) (or by an optional mains adaptor of 9 V) |
Auto shut-off | yes, 5 minutes to protect battery power |
Dimensions | device: 203 x 76 x 38 mm thermal sensor: 8 mm diameter x 940 mm maximum extended length (only 280 mm when contracted) |
Enclosure | ABS plastic |
Weight | 515 g |