Product Details

high sensitivity LF-1200 air and water disinfector/ozone air fresheners/ozone sensor

Place of Origin Guangdong, China
Brand Name Long life O3
Model Number LF-1200

Product Features

high sensitivity LF-1200 air and water disinfector/ozone air fresheners/ozone sensor

 

Specifications:

 

The ozone gas alarm is intelligent instrument with a multifunctional, adopts advanced signal processing techniques, combination of hardware and software to realize the ozone measurements of high performance and low cost, the ozone sensor adopts imported HMOS ozone semiconductor devices, high sensitivity, rapid response, high precision, long service life, is very suitable for ozone leakage monitoring the alarm

 

Technical parameters:

 

Measurement   object

Ozone in the air

Sensor Type

Heating type   metal oxide semiconductor sensor or an electrochemical sensor

Measuring range

0-1ppm   (resolution 0.001ppm);

0-100ppm   (Resolution 0.001ppm, 0.01ppm)

Measurement accuracy

0.001ppm;0.01ppm;±3%FS

Analog Output

Optional 0-5V or   4-20mA (9 ADC)

Digital output

RS485

Power supply

12V DC   (standard) (24V DC optional)

Semiconductor sensor accuracy depends on the heating time is recommended first energized more than 24 hours to ensure accurate readings, after a short period of time useless, powered up again to warm up for at least 10 minutes, more than 1 week is recommended warm-up for 24 hours.

 

Sensor   Interface

1

2

3

4

 

5V+

HEAT

SIGN

GND

 
 

 

 

Output

Interface

1

2

3

4

5

6

7

Relay output

4~20MA+

4~20MA-

RS485A

RS485B

NOP

         

 

 

Power connector: 5.5 x 2.1 mm DC power connector

 

Sensor Interface: 4-core plug (Ø12)

 

Output Interface: core plug (Ø12)

 

Relay Output: normally open type contacts largest AC250V, 10A

 

Analog output: 0-5V and 4-20mA can not be used at the same time need to be specified when ordering, 0-5V output is non-positive and negative short-circuited

 

Show: four red LED display;

 

Run: run light, normal working hours flashes per second;  ALARM: The alarm indicator, the ozone concentration is greater than the set alarm concentration Always, normally open relay closes.

Alarm point for the method:

 

1: Press and hold the SET key for more than 3 seconds, running lights and alarm indicator light, into the set, displays the current alarm value;

 

2: Press : alarm value increases, the value decreases ,Press alarm; Press and can be quickly adjusted;

 

3: adjustment is completed, press the SET button to return to run the interface, run the light is blinking;
Fault information:

 

1: ALARM light: ozone concentration values greater than the set alarm value, the concentration of ozone gas automatic recovery

 

2: ERR: sensor failure, check the connection is normal, or contact the manufacturer to replace the sensor

 

3: Display OVER: ozone concentrations exceeding the sensor range

 