car batteries dry battery DIN45,MF54519
car batteries dry battery DIN45,MF54519
car batteries dry battery DIN45,MF54519

car batteries dry battery DIN45,MF54519

USD $1 - $18 /Set

Min.Order:50 Sets

Supply Ability:
24000 Set / Sets per Month
Port:
Shenzhen
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
China
Brand Name:
EASTAR or OEM
Model Number:
DIN45
Usage:
Other, Car, starting
Voltage:
Other, 12v
Sealed Type:
Sealed

Shenzhen Eastar Battery Co., Ltd.

Business Type: Manufacturer
Shenzhen Guangdong China
Main Products: Dry battery ,Lead Acid Battery ,NI-MH battery ,Ni-CD battery ,Li-ion battery

Product Details

Product Description

12V battery 

1)CE, ISO9001 
2)good start-up capability 
3)low self-discharge 
4)Excellent Starting Performance

12V battery DIN45 dry charged auto/automobile/car starting battery JIS

 

Specification:

DIN ModelNew Type
(JASO)
Voltage
(V)
Capacity
(AH)
Dimensions(mm)Weight
 (kg)
Cranking Ampere at -15 °C(Amp)Cell Layout
(Fig No)
Terminal
Type
L*W*H/T.H
54519/DIN45-1245245*175*175mm11.12500-B4A

 

Attention:

1) Do not handle battery roughly.

2) Do not drop water in the battery before electrolyte is filled.

3) See instructions before putting into service.

4) Sulphuric acid cause severe burn.

5) Keep away from spark.

6) Danger!Explosive

7) Wear goggle

Instruction for Putting Into Service

 

1) Fill cells with electrolyte(refined sulphuric acid) having a specific gravity as given in Table 1 to the proper level as given in Figure 1 When filling the electrolyte, temperature must not be lower than 15°C nor higher than 30°C. Note: if battery vent plugs are sealed with tapes, discard sealing tapes.

 

2) Allow battery to stand for some time after filling before placing on charge. If electrolyte level has drop, add more electrolyte until proper level is reached.

 

3) Place on charge at the proper rate as given in Table 13, charge until cell gases freely, and the voltage and specific gravity are constant over three times successive readings taken at 30 minutes intervals.

 

4) During the charge, do not allow electrolyte temperature to rise above the value as given in Table 1. Should this temperature be reached, reduce charging current. Electrolyte temperature is below -15°C, charge at a half of less of the proper current in the long time, or charge at normal charging current after keeping the battery in a warm room for about 24 hours.

 

5) Dont fill a hole of vent plugs

 

6) Keep vent plugs tight

 

7) Consider that the battery should be kept warm and that charge states should be accurate in order to keep electrolyte free from freezing in the cold season.

 

8) Grounded terminals of the battery are desirable to be disconnected in a long standing period installing battery in vehicle.

 

9) The battery should not be attached to petroleum or contacted to vinyl chloride.

 

Table 1

 

SG of electrolyte required under full charged.(20°C)

Hot Climate 1.240

Tropical Climate 1.260

Cold Climate 1.280

SG of sulphuric acid for filling new Cells. (20°C)

1.230-1.240

1.250-1.270

1.270-1.290

SG of electrolyte at end of charge (fully charged)(20°C)

1.230-1.240

1.250-1.270

1.270-1.290

Maximum permissible temperature of electrolyte during charge

50°C

45°C

45°C

 

Table 1

 

SG of electrolyte at end of charge (fully charged). (20°C)

1.240

1.260

1.280

Value of SG of electrolyte. (20°C)

Less than 1.190

Less than 1.200

Less than 1.220

 

General Notice

 

1)Battery should be secured firmly in the vehicle in a proper manner.

 

2)Charge battery fully as soon as it is over discharge.

 

3)An open flame or spark should not be brought too close to the battery.

 

4)If the temperature of electrolyte is extremely low, it is difficult to determine whether battery is fully charged and charging efficiency becomes poor. Therefore, when be sure marked POS cable is connected to POS (+) terminal. Connect NEG(-) cable last to prevent dangerous sparks. DO NOT OVER TIGHTEN! Its a good idea to install special corrosion retarding fiber washers around terminals to help extend battery life.

 

5)Side terminal batteries need special care. Over tightening the terminal bolts will severely damage the battery and could cause a dangerous explosion. Use a special side terminal torque tool to avoid this hazard.

 

6)Coat the terminals and exposed metal parts around the battery with a good quality protective spray.

 

Table 3

 

Initial charge current  AMP

0.08XC

Normal Charge current  AMP

0.1XC

C: Battery Capacity (Amp) at 20 hour rate 


 

 

 

 

Packaging & Shipping

 car batteries dry battery DIN45,MF54519car batteries dry battery DIN45,MF54519

Company Information

 car batteries dry battery DIN45,MF54519car batteries dry battery DIN45,MF54519car batteries dry battery DIN45,MF54519car batteries dry battery DIN45,MF54519car batteries dry battery DIN45,MF54519

Contact Supplier

Ms. marisa Shaw Manager Chat Now
Telephone
86-755-22214426
Mobile
86-15019407951
Fax
86-755-25691144
Address
Room905, Hongchang Plaza, Shennan Road East, Luohu Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Batteries > Storage Batteries
Categories
Hi~