CS9913AS 5KV ac Programmable Hipot Tester
Negotiable /Piece
Min.Order:1 Piece
Nanjing Allwin Instrument Science And Technology Co., Ltd.
·AC/DC withstanding voltage function
·Innovative Security Protection System
·Using DDS Principle to generate the accurate, stable, pure and less distortion sine waveform
·The rise and decline time of high voltage can be adjustable. It can meet the different requirements of different users
·Arc detection with two options modes of the current mode and the level mode
·Test results can be saved simultaneously and it support more complete statistical analysis operations
·Comprehensive testing with double frequency, range from 50Hz and 60Hz
·With open-circuit and short-circuit detection
·User-friendly interface, users can input data using front keys directly or using dial input. The operation ismore simple and accurate.
·Complete help tips of operation, effectively improve the efficiency of work.
·With TNT color LCD display, the measurement results is much clearer and more informative
·Test step, the system state information display synchronized. Users are easy to understand the testprocedure in testing for more information and system status
·Support the input of Character file names, whose maximum length can be up to 12 characters
·Supporting new, delete, jump and other shortcuts of documents and test step. It is facilitate for users to manage the test files.
·Supporting system log, recording the boot time, the total running time, the number of tests and other parameters of this instruments, It is facilitate for users to understand the information of instruments.
·Chinese and English bilingual interface to adapt to the needs of different users
·Support mass storage, can support file organization format for 50 files * 40-step test,
25 files * 80 steptest,10 files * 200 step test,5 files * 400 step test. It is suitable for
different application requirements ofthe test
·The minimum resolution of ACW is 0.1uA, 0.1V; the minimum resolution of DCW is 0.01uA, 0.1V,
the minimum resolution of insulation resistance test 0.001Mohm, 0.1V
·Support RS232/RS485/PLC/GPIB/USB / Ethernet, printer interface and other communication interfaces
Technical parameters
Model | CS9913AS | CS9913BS | CS9914AS | CS9914BS | ||
ACW | output voltage | range | 0.050kV~5.000kV | |||
accuracy | ±(1%reading value+5V)voltage≥1.000kV ±(2%reading value+5V)voltage<1.000kV | |||||
resolution | 1V volts/Step | |||||
maximum output power | 250VA(5.000kV/50mA) | 500VA(5.000kV/100mA) | ||||
maximum rated current | 50mA | 100mA | ||||
lower limit current range | 0~50mA,0=not judge the lower limit | 0~100mA,0=not judge the lower limit | ||||
current gear | 200uA,2mA,20mA,50mA | 200uA,2mA,20mA,50mA,100mA | ||||
output waveform | sine wave | |||||
output waveform distrotion | ≤2%(No load or pure resistance load) | |||||
voltage rise time | 0.5s~999.9s 0=voltage rise time off | |||||
test time | 0.1s~999.9s 0=continuous test | |||||
voltage descend time | 0.5s~999.9s 0=voltage descend time off | |||||
interval time | 0.1s~999.9s 0=test time is up,tester stops automitically | |||||
arc detect | (0.00-20.00)mAac/(0-9) 0=off | |||||
arc detect time | (0.0-999.9)sec 0=Disable | |||||
output voltage mode | N mode,G mode | |||||
Model | CS9913BS | CS9914BS | ||||
DCW | output voltage | range | 0.05kV~6.000kV | |||
accuracy | ±(2%reading value+5V) | |||||
resolution | 1V | |||||
maximum output power | 120W(6.000kV/20mA) | 300W(6.000kV/50mA) | ||||
maximum rated current | 20mA | 50mA | ||||
current gear | 2uA,20uA,200uA,2mA,20mA | 2uA,20uA,200uA,2mA,50mA | ||||
ripple factor | ≤5% | |||||
discharge time | ≤200ms | |||||
maximum charging current | 20mA | 50mA | ||||
voltage rise time | 0.3~999.9s 0=voltage rise time off | |||||
test time | 0.3~999.9s 0=continuous test | |||||
voltage descend time | 0.3~999.9s 0=voltage descend time off | |||||
interval time | 0.0~999.9s 0=interval time off | |||||
delay alarm time | 0.3~999.9s 0=delayed alarm time off | |||||
output voltage mode | N mode,G mode | |||||
arc detect | (0.00-10.00)mAac/(0-9) 0=off | |||||
arc detect time | (0.0-999.9)sec 0=Disable | |||||
Model | CS9913AS | CS9913BS | CS9914AS | CS9914BS | ||
voltmeter | range | 0.050kV~5.000kV(AC) 0.050kV~6.000kV(DC) | ||||
accuracy | ±(1%reading value+5V)voltage≥1.000Kv ±(2%reading value+5V)voltage<1.000kV | |||||
resolution | 1V | |||||
showing data | root-mean-square value | |||||
ampere meter | measurement range | AC | 0 ~ 50mA | 0 ~ 100mA | ||
DC | 0 ~ 20mA | 0 ~ 50mA | ||||
resolution | AC | £ 2mA is 0.001mA,> 2mA is 0.01mA | ||||
DC | £ 2mA is 0.001mA,> 2mA is 0.01mA | |||||
measurement accuracy | ±(2%reading value+2words) | |||||
offset function | the current of test line and accessories can be subtrcted . | |||||
test mode | GND mode:RETURN terminal connect with casing FLOAT mode:RETURN not connect with casing | |||||
timer | range | 0~999.9s | ||||
resolution | 0.1s | |||||
accuracy | ±(0.1%+50ms) | |||||
memory group/test step | 50sets/40steps |
SAFETY TESTING STANDARDS
REAR PANEL
CE
ISO
Accessory