SPC01/SPC02 Demo Board for Wireless Transceiver RF Module
USD $47 - $50 /Piece
Min.Order:1 Piece
NiceRF Wireless (Shenzhen) Technology Co., Ltd.
SPC01/SPC02 Demo Board for Wireless Transceiver RF Module
Pictures:
Schematic:
LEDs:
Part Name | Part Type | Function |
Pedo | Led | Reserved; no function |
Temp | Led | Temperature indication |
Pres | Led | Pressure indication |
Alti | Led | Altitude indication |
Comp | Led | Direction indication |
Weat | Led | Weather trend indication |
BUTTONs:
MODE: This button is used to switch measured parameters in different mode.
Startcal: At each powering-on, the compass sensor needs to be recalculated. After pressing it, the DISPLAY area will show "---", which means calibration is going on. Users need to rotate the demo kit horizontally at least two times and each circle should last at least 3 seconds.
Exitcal: Reserved; without function.
Wakeup: It is used to wake up the module from sleep mode.
Sleep: When it is pushed, the module will enter sleep mode.
SWITCH & SOCKET
Part Name | Part Type | Function |
J1 | Fig | To fix sensor module on board |
J2 | Header | Pin header for battery supply |
K6 | Switch | Power switch |
S1 | Socket | Power socket for DC input |
D6,D7 | Display | Display measured parameters |
J5,J6 | Pin holes | For monitoring command and time sequence |
J7 | Jumper | Connected; reserved |
POWPER SUPPLY
The kit works at 2.7~3.6V. There are two groups of power inputs: J2 (battery) and S1
(DC socket). Users only can choose one of them in use.
FUNCTION DISCRIPTION
When powering-on, the DISPLAY will show pressure value and the Pres LED is lighted. Users can push the Mode button to check different parameters. At each power-on, the compass sensor needs to be recalculated or else the measured value is inaccurate. After pressing Startcal button, the DISPLAY will show ‘---‘ and the compass sensor will start self-calculation and last about 10 seconds. In this period users need to rotate the demo kit horizontally at least two times and each circle should last at least 3 seconds. After self-calibration the DISPLAY will show the accurate compass value.
APPLIATION NOTES
* SPC module should be kept away from the outlet of wind in measuring pressure value. Dust or other foreign substance should not block or cover the measuring hole of pressure sensor or else the pressure value will be inaccurate or be postponed in reading.
* In measuring direction the module should be kept in horizontal level in order to get the correct value and should avoid to be used in strong magnetic environment such as large electromechanical equipment, iron mine, magnet, etc. If the product is equipped with speaker, the speaker should be turned off in case the magnetic field will interfere the compass.
* If the sensor module is put or pass in strong magnetic environment, the compass should be calibrated after leaving such environment. The users also need to calibrate the compass for the first use when the finished products are sold on market