Product Electric Parameters |
Input specification | Input voltage | AC90V---264V |
Input frequency | 47-63Hz |
Input surge | 20A@ 120VAC 20A@230VAC |
Output specification | Output voltage can be adjusted | ±10% |
Start-up time | ≤1S(input230V,Io=100%) |
keep time | ≥20mS (input230V,Io=100%) |
Voltage regulation | (Full load) ≤0.5% |
Protection function | Overload protection | 105% - 150% rated power, automatic recovery |
Over-voltage protection | 105% - 150% of the rated voltage |
Insulation intensity | Input---output | 1500VAC/1min |
Input---ground | 1500VAC/1min |
Input---ground | 500VAC/1min |
Safety standards | According with GB4943, UL60950-1,EN60950-1 standards. |
E M C standards | According with GB9254, EN55022 class A EN61347-2-13:2008 standard |
Environmental | Working temperature | - 20 ° ~ 60 ° c / 20% ~ 90% RH (no frost) |
Storage temperature | - 40 ° ~ 85 ° c/10% ~ 95% RH (no frost) |
height above sea level | ≤2000M |
structure | Size (mm) | 155(L)*103*(W)*45(H) |
Cooling method | Cooling method | Natural cooling air convection |
Weight | 0.5KG/PCS |
Product Type Table |
Product model | output specification | ripple, noise | efficiency |
FY-50-5 | 5V | 10A | 70mV | 78% |