CMEF hottest mobile Hemodialysis Machine for hospitals with competitive price MSLHM01-N
USD $49 - $10,000 /Set
Min.Order:1 Set
Guangzhou Medsinglong Medical Equipment Co., Ltd.
This Hemodialysis Machine is equipped with intelligent operation system. Easy operation with visual and audio alarms; Multi-purpose service/maintenance interface; sodium concentration and UF curve.
Main performance of this Hemodialysis device
1.Self-checking function;
2.Carbonate dialysis;
3.Double needle dialysis;
4.Liquid level detector;
5.Bubble detector;
6.Blood leakage detector;
7.Temperature and electric conductivity monitoring;
8.Arterial pressure, venous pressure and transmembrane pressure monitoring;
9.Rolling blood pump;
10.Heparin pump;
11.Dehydration amount controlled by capacity;
12.Automatic disinfection cleaning program;
13.Stand-by power of blood pump in case of power failure;
14.Information display function of display screen.
It is designed and manufactured in strict accordance with the Requirements of national laws and regulations. The reference standards of design and manufacture are following: GB9706.1-2007; GB9706.2-2003; and YY0054-2003.
Technical Parameter of hemodialysis machine
1. Size & Weight
Size: 380mmx400x1380mm (L*W*H);
Area: 500*520mm;
Weight: 88KG;
2. Power supply
AC220V, 50Hz/60Hz, 10A
Input power: 1500W
Back-up battery: 30 minutes (optional)
3. Working Condition
Water input pressure: 0.1Mpa~0.6Mpa, 15P.S.I~60P.S.I
Water input temperature: 5℃~30℃
Working environment temperature: 10℃~30℃ at relative humidity <70%
4. UF rate
Flow range: 0ml/h~4000ml/h
Resolution ratio: 1ml
Precision: ±30ml/h
5. Blood pump &Spare pump
Blood pump flow range: 30ml/min~600ml/min (diameter: 8mm or 6mm)
Spare pump flow range: 30ml/min~600ml/min (diameter 8mm or 6mm)
Resolution ratio: 0.1ml
Precision: ±10ml or 10% of reading
6. Heparin pump
Syringe size: 20, 30, 50ml
Flow range: 0ml/h~10ml/h
Resolution ratio: 0.1ml
Precision: ±5%
7. Monitoring system &Alarm setup
Venous pressure: -180mmHg ~ +600mmHg, ±10mmHg
Arterial pressure: -380mmHg ~ +400mmHg, ±10mmHg
TMP pressure: -180mmHg ~ +600mmHg, ±20mmHg
Dialysate temperature: preset range 34.0℃~39.0℃
Blood leak detection: Photo chromic alarm when erythrocyte specific volume is 0.32±0.02 or blood leak volume is equal or more than 1ml per liter of dialysate.
Bubble detection: Ultrasonic, Alarm when a single air bubble volume is more than 200μl at 200ml/min blood flow
Conductivity: Acoustic-optic
8. Disinfection/Sanitize
Heat disinfection:
Time: 30 minutes; Temperature: about 80℃, at flow rate 500ml/min;
Chemical disinfection:
Time: 30minutes, Temperature: about 36℃~50℃, at flow rate 500ml/min;
Chemical disinfection with heat:
Time: 45minutes, Temperature: about 36℃~80℃, at flow rate 50ml/min;
Rinse:
Time: 10minutes, Temperature: about 37℃, at flow rate 800ml/min;
Storage Environment:
Storage temperature should be between 5℃~40℃, at relative humidity <80%
Our haemodialysis machine is working in the world most famous hospital-Huaxi, providing dialysis treatment for patients (real time photos)