new products infant radiant warmer with CE certificate
USD $500 - $5,000 /Piece
Min.Order:1 Piece
Zhengzhou Dison Instrument And Meter Co., Ltd.
BN-200(Luxurious) Infant Radiant Warmer
Brief introduction:
Three modes of control: manual, skin temperature and mattress temperature
Alloyed bracket, fastness
Microprocessor based servo controlled temperature system
Control panel displayed by VFD
Digital skin temperature sensor, the data is exact and stabilizability
High sensitivity and untouched detector to inspect mattress temperature
Alarm functions for safety include
power failure temperature deviation
temperature probe failure over temperature
APGAR timer to record therapy time
Observe light angle can be adjusted + 90º, and the brightness adjusted
Heater head can be adjusted + 90º horizontally
Electric infant bed tilt angle is + 10º, transparent protector folded
Convenient X-ray cassette under infant bed
Electric height adjusted suit for operation
Adopts anti-explosion micro crystal quartz infrared radiation tube for its radiation source, the heating is quick and life-span is long
Alarms are audible and visual
A second thermal cut-out function for more safety
Skin temperature sensor failure protect function avoid over temperature
Standard configuration
Main body (including the radiant source, control system, infant bed, electric lift stand),I.V.pole, skin sensor, mattress, one drawer, transparent protector, castors
Optional parts: low pressure aspirator; oxygen supply system , LED phototherapy unit.
Technical data:
2. Power input: ≤1000VA
3. Operating condition
An ambient Temperature:18°C-30°C
An ambient Relative Humidity: 30%--75%RH
Atmospheric Pressure: 700~1060 hPa
An ambient Air Velocity <0.3m/s
4.Range of Skin Temperature control: 32°C~38°C
5.Temperature control accuracy: ≤0.5°C
6.Alarms functions:
a. Over temperatuer :>39°C
b. A sencond thermal cut- out : 40°C
c. Sensor alarm: skin temperature sensor failure
matterss temperature sensor failure
room temperature sensor failure
7.Mattress temperature uniformity : <2°C
8.Skin temperature sensor accuracy: ≤0.3°C
9.Mattress temperature sensor accuracy: ≤0.4°C
10.Room temperature sensor accuracy: ≤0.3°C
11.Warm-up time: ≤30min
12.Height adjustable range:0-20CM
13.Bed tilt angle:+ 10°
14.APGAR timer range: ≤24h
15.Heater head horizontal: ±90°
16.Mattress size:76CM X 65CM
17.Distance from heater to mattress: 90CM
18.Whole unit size: 70CMX 110CMX 180CM(180-200CM)
19. Castor load: 1pc≤200kg 4pcs≤800kg
Transport and storage
Environment Temperature:-40°C~ +55°C
Environment Relative Humidity: ≤95%
Atmospheric Pressure: 500~1060hPa
Package:
Each unit is packed one case
Size:114CMX 94CM X 104CM
Gross weight: ≤190KG