Hydraulic pump tester MYTH-1-5
USD $1,300 - $2,700 /Set
Min.Order:1 Set
Ji'nan High Land Hydraulic Pump Co., Ltd.
portable Hydraulic Testing Gauge MYHT-1-5 hydraulic pressure
This products is called the "First-Aid Case”, if the hydraulic equipment have something when it works outdoor, it is not easy to check out which part has the problem, and now you can take our tester, and connect with pump or motor or cylinder to check, it will help you to improve the efficience.
Application:
MYHT portable hydraulic testing gauge ,which is used for checking and surveying hydraulic system's discharge .Pressure and temperature , is the initiation in china ,and has gotten the country patent .
Warning:
The loading valve should be at turn-on position. Otherwise, danger will arise.
Only the test result is precise with oil temperature kept at 30
°Cor above
Open loading valve before test
Cut off power after completion of test
Maintenance:
Load valve: In correct connection of power, if the load valve could not work, check if there is any jam inside it.
Battery: The battery is able to continuously work over 30 hours and should be charged 4—8 hours for one time.
Flow Meter: It might because of pollutant if the flow meter is not able to show data normally. In this case, contact the manufacturer to solve this problem.