RSP-2000 Meanwell 2000W laser related machine power supply Quality Choice
USD $1 - $10 /Piece
Min.Order:1 Piece
Hangzhou Gunan Technology Co., Ltd.
RSP-2400 Meanwell 2400W power transformer for burn-in facility
OEM high quality hot galvanized Solar Energy Ground Spiral pile,screw pile
China OEM hot galvanized Solar Ground pile,Spiral pile,screw pile
hot galvanized Ground screw piles,Spiral piles,fence posts for sale
hot galvanized Spiral piles,screw piles steel pipe welding service
MODEL | RSP-2000-12 | RSP-2000-24 | RSP-2000-48 | ||
OUTPUT | DC VOLTAGE | 12V | 24V | 48V | |
CURRENT RANGE | 0 ~ 100A | 0 ~ 80A | 0 ~ 42A | ||
RATED CURRENT | 100A | 80A | 42A | ||
RATED POWER | 1200W | 1920W | 2016W | ||
RIPPLE & NOISE (max.) | 150mVp-p | 200mVp-p | 300mVp-p | ||
VOLTAGE ADJ. RANGE | 10.5 ~ 14V | 21 ~ 28V | 42 ~ 56V | ||
VOLTAGE TOLERANCE | 2.0% | 1.0% | 1.0% | ||
LINE REGULATION | 0.5% | ||||
LOAD REGULATION | 0.5% | 0.5% | 0.5% | ||
SETUP, RISE TIME | 1500ms, 60ms at full load | ||||
HOLD UP TIME (TYP) | 16ms/230VAC 16ms/230VAC at 75% load 10ms/230VAC at full load | ||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC / 170 ~ 370VAC selected by switch 240 ~ 370VDC | |||
FREQUENCY RANGE | 47 ~ 63Hz | ||||
EFFICIENCY (Typ.) | 86% | 90.5% | 92% | ||
AC CURRENT (Typ.) | 13A/115VAC 7A/230VAC 16A/115VAC 11A/230VAC | ||||
INRUSH CURRENT (Typ.) | 25A/115VAC 50A/230VAC | ||||
LEAKAGE CURRENT | <2.0mA / 240VAC | ||||
PROTECTION | OVER LOAD | 105 ~ 150% rated output power | |||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | |||||
OVER VOLTAGE | 14.7 ~ 17.5V | 29.5 ~ 35V | 57.6 ~ 67.2V | ||
Protection type : Shut down o/p voltage, re-power on to recover | |||||
OVER TEMPERATURE | 85oC 5 (TSW2 ) detect on heatsink of O/P diode; 75oC 5 (TSW1 ) detect on heatsink of power transistor | ||||
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down | |||||
FUNCTION | DC OK SIGNAL | The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V | |||
OUTPUT VOLTAGE TRIM | Adjustment of output voltage is possible between 20 ~ 110% of rated output | ||||
CURRENT SHARING(CS) | Please refer to function manual | ||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70oC (Refer to output load derating curve) | |||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||
STORAGE TEMP., HUMIDITY | -40 ~ +85oC, 10 ~ 95% RH non-condensing | ||||
TEMP. COEFFICIENT | 0.02%/oC (0 ~ 50oC ) | ||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||
SAFETY &EMC | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved | |||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) | ||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A | ||||
OTHERS | MTBF | K hrs min. MIL-HDBK-217F (25 ) | |||
DIMENSION | 295*127*41mm (L*W*H) | ||||
PACKING | Kg; |