25w Meanwell Constant Voltage led driver APV-25-5/APV-25-12/APV-25-15/APV-25-24/APV-25-36
USD $1 - $10 /Piece
Min.Order:1 Piece
Hangzhou Gunan Technology Co., Ltd.
HLG-40H 40W Meanwell power supply adjustable dimming driver for park lighting
HLG-60H 60W Meanwell waterproof dimmable driver for street light,bay light and flood light
HLG-150H 150W led driver Meanwell IP67 for street light,bay light and flood light
HLG-185H 185W Meanwell led driver for street light,bay light and flood light
MODEL | APV-25-5 | APV-25-12 | APV-25-15 | APV-25-24 | |||
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | ||
CURRENT RANGE | 4A | 2.1A | 1.67A | 1.05A | |||
RATED CURRENT | 0~4A | 0~2.1A | 0~1.67A | 0-1.05A | |||
RATED POWER | 25W | 25W | 25W | 25W | |||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | |||
VOLTAGE TOLERANCE Note.3 | 5.0% | ||||||
LINE REGULATION | 1.0% | ||||||
LOAD REGULATION | 2.0% | ||||||
SETUP, RISE TIME | 1500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load | ||||||
HOLD UP TIME (Typ.) | 20ms/230VAC 15ms/115VAC at full load | ||||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 76% | 79% | 80% | 82% | |||
AC CURRENT (Typ.) | 0.3A/230VAC 0.5A/115VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 35A/115VAC 70A/230VAC | ||||||
LEAKAGE CURRENT | 0.25mA / 240VAC | ||||||
PROTECTION | OVER CURRENT | Above 105% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 5.75 ~ 6.75V | 13.8 ~ 16V | 17.5 ~ 21V | 28 ~ 32V | |||
Protection type : Shut off o/p voltage, clamping by zener diode | |||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70 (Refer to output load derating curve) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80 , 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | 0.03%/ (0 ~ 50 ) | ||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | ||||||
SAFETY &EMC(Note 4) | SAFETY STANDARDS | Design refer to TUV EN60950-1, EN61347-2-13,UL8750 | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH | ||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B,EN55015,EN61547 | ||||||
HARMONIC CURRENT | Compliance to EN61000-3-2 Class A, EN61000-3-3 | ||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level(surge 2KV), criteria A | ||||||
OTHERS | MTBF | Khrs min. MIL-HDBK-217F (25 ) | |||||
DIMENSION | 84*57*29.5mm (L*W*H) | ||||||
PACKING | 0.13Kg; 72pcs / 10.4Kg / 0.92CUFT |