Highland hydraulic vane pump pressure test kit
USD $1,000 - $3,000 /Unit
Min.Order:1 Unit
Ji'nan High Land Hydraulic Pump Co., Ltd.
Hydraulic Pump Test Bench
Motive Power: Ordinary electromoter; Frequency conversion electromoter; Hydraulic electromoter; diesel engine drive ;diesel engine hydraulic drive
Pressure: 35Mpa; 42Mpa
Power: 7 5kw;90 kw ;110 kw; 160 kw
Load Location: Locale; Long distance
Provide oil: oblige; absorb
Show location: Locale; Computer
Working medium: hydraulic oil
Oil tank cubage: 2000L; 3400L
Oil filtrate: 2 degree filter; 4degree filter; filtrate equipment
Cooling way: wind cooler; water cooler
Accessories: Connect shaft (2 Pc) ; outline drawing of shaft( 1 pc)
Hydraulic test bench is the special equipment for the delivery inspection of components for manufacturers of hydraulic pumps and hydraulic motors. The system adopts quality hydraulic components made both at home and abroad. And the accessories feature compact structure, reliable quality, reasonable design, as well as easy operation and maintenance. The product is of internationally advanced level.
The test bench adopts advanced power recovery technology in the world, which can save energy by over 70%. All the valves are of cartridge structure, and it has the advantages of simple collocation, stable performance, low trouble rate and easy maintenance.
The equipment can be controlled either manually or automatically through computerized control, which makes it simpler to operate.
1. Supply electricity: turn on the the control switch
2. Turn on the computer
3. Turn on the instrument switch (the switch has three gears: the Median is closed. Dextral is to test the motor. Left is to test the pump.) Clearing to zero -- Press the button long time
4. Double-click on the logo to enter the operation interface
5. Press the button manually / Automatic election (Generally choose the former at first)
6. Change-over the switch to dextrorotation or left according to the rotation of the pump
7. Clearing the Proportion controller to zero
8. Turn on the switch of the Proportion controller to supply electricity
9. Clearing all of the upload and speed regulation to zero