SZL series 2-35t/h coal fired double-cylinder steam boiler
Negotiable /Set
Min.Order:1 Set
Wuxi Yunna Materials Co., Ltd.
SZL series 2-35t/h coal fired double-cylinder steam boiler
SZL packaged water-tube steam boiler is the double-cylinder,water-tube assembly,chain grate boiler.Two cylinders are laid at the upper and lower level of boiler longitudinally along the center.Front section of the upper cylinder and water-cooled tubes at side walls form the radiation-heating area in the hearth.While the rear section and tube bank in the lower cylinder serve as convection-heating area.Coal econnomizer is mounted at the rear of bolier.Some heat of hot combustion fume is absorbed by the hearth.Then hot combustion heat flows to the convection heating area through cooling chamber and exhausts outside with the chimney via coal economizer,dust collector and draught fan.
Compact soize,small installation spaxe,single-floor boiler room,cost-effective omfrastructure.
Great assembily level,short installation period and cheap installation.
Sufficient and reasonable heating area,quick temperature/pressure-rise of boiler,satisfactory productivity and high heating efficiency.
Introduce the air with air distribution chambers of grate.All air distribution chambers can adjust the air flow indepedently and grate speed can be regualated in the stepless way.Wide range of applicable coals.Thorough combustion.
Electrical cabinet is equipped with complete automatic control and monitor instruments featuring high automation,safety,reliability and simple operation.
Heating capacity:2-35t/h ,pressure:1.0-2.5MPa
Model | SZL6-1.25-AII | SZL8-1.25-AII | SZL10-1.25-AII | SZL15-1.25-AII | SZL20-1.25-ALL | SZL25-1.25-ALL | SZL30-1.25-ALL | SZL35-1.25-ALL | |
SZL6-1.6-AII | SZL8-1.6-AII | SZL10-1.6-AII | SZL15-1.6-AIISZL15-2.5-AII | SZL20—1.6-ALL | SZL25-1.6-ALL | SZL30-1.6-ALL | SZL35-1.6-ALL | ||
SZL6-2.5-AII | SZL8-2.5-AII | SZL10-2.5-AII | SZL20-2.5-ALL | SZL25-2.5-ALL | SZL30-2.5-ALL | SZL35-2.5-ALL | |||
Rated heating efficiency(MW) | 6 | 8 | 10 | 15 | 20 | 25 | 30 | 35 | |
Rated working pressure(MPa) | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | 1.25/1.6/2.5 | |
Rated steam temperature(°C) | 193/204/226 | 193/204/226 | 193/204/226 | 193/204/226 | 193/204/226 | 193/204/226 | 193/204/226 | 193/204/226 | |
Water-supply temperature(°C) | 60 | 60 | 60 | 60 | 104 | 104 | 104 | 104 | |
Heating area | Boiler (m2) | 156 | 197.4 | 235.6 | 335 | 412 | 508 | 510 | 588.6 |
Coal economizer (m2) | 87.2 | 157 | 174.4 | 354 | 413/413/236 | 357 | 496 | 450 | |
Air preheater (m2) | -/-/181 | 199 | 212 | 210 | |||||
Effective area of grate (m2) | 7.8 | 10.1 | 11.8 | 17.3 | 21 | 24.3 | 25.8 | 37.7 | |
Water volume(m³) | 7.3 | 9.6 | 12.4 | 15.3 | 21.6 | 27 | 27.6 | 31.8 | |
Design efficiency(%) | >80 | >80 | >80 | >80 | >80 | >80 | >80 | >80 | |
Applicable fuel | Soft Coal Class II and III | ||||||||
Maximum size of shipping part(m) | 6.1×3.1×3.5 | 6.8×3.4×3.5 | 7.6×3.4×3.5 | 9.6×3.4×3.54 | 11×3.41×3.54 | 8.3×3.0×3.6 | 8.5×3.6×3.64 | 8.5×3.8×3.8 | |
Maximum weight of shipping part(t) | 25 | 29 | 31 | 42 | 50 | 22/28 | 23/29 | 24 | |
Overall size of installation(m) | 9.5×5.5×6.2 | 9.5×5.5×6.2 | 9.8×5.7×6.2 | 10.9×5.7×6.7 | 12×5.8×6.8 | 13.8×6.0×10.6 | 18×6×10.5 | 18×8×3.8 | |
Draught fan | GY6-1 30kw | GY10-1 45kw | GY10-15 55kw | Y5-47 12D 75kw | GY5-47 12.4D 90kw | GY20-15 110kw | GY35-15 132kw | Y4-73 14D 185kw | |
Blower fan | T4-72 5A 11kw | GG10-1 15kw | GG10-1 15kw | G4-73 9D 30kw | G4-73 9D 30kw | GG20-15 55kw | G40-73 10D 55kw | G4-73 10.5D 75kw | |
Speed governor | GL-10P 0.75kw | GL-16P 1.1kw | GL-16P 1.1kw | GL-20P/II 1.5kw | GL-20P/Ⅱ 1.5kw | GL-30P 2.2kw | GL-40P 3kw | GL-40P 3kw | |