MSQ-60 type Class 0.5 transformer manufacturer
USD $5 - $8 /Piece
Min.Order:320 Pieces
Zhejiang Dixsen Electrical Co., Ltd.
Model | Ratio (A) | Burden(VA) | Case Qty.(Pcs) | Item Code | |
Class: 0.5 | Class: 1.0 | ||||
MSQ-60 | 250/5 | 1.5 | 2.5 | 32 | 106002505 |
MSQ-60 | 300/5 | 2.5 | 5 | 32 | 106003005 |
MSQ-60 | 400/5 | 5 | 10 | 32 | 106004005 |
MSQ-60 | 500/5 | 5 | 10 | 32 | 106005005 |
MSQ-60 | 600/5 | 5 | 10 | 32 | 106006005 |
MSQ-60 | 750/5 | 5 | 10 | 32 | 106007505 |
MSQ-60 | 800/5 | 7.5 | 10 | 32 | 106008005 |
MSQ-60 | 1000/5 | 10 | 15 | 32 | 106010005 |
MSQ-60 | 1200/5 | 10 | 15 | 32 | 106012005 |
MSQ-60 | 1500/5 | 15 | 15 | 32 | 106015005 |
MSQ-60 | 1600/5 | 15 | 15 | 32 | 106016005 |
Note: Class/VA rating must be mentioned when ordering.
CT consist of primary winding, secondary winding, magnetic core and insulated body. The high-grade silicon steel core is annealed, varnished then insulated with polycarbonate core caps. The secondary winding is toroidally wound by high precision semi-automatic machinery. For the tape wound ring type current transformer, the PEW coated windings are then covered with elephantite paper, varnished and double-tapped with PVS tapes. For the encapsulated type current transformer, the windings are enclosed in a compact and heat resistant split cap.
1. Improper selection, installation or operation can cause danger to personal security.
2. Don't open the secondary circuit when the current is avaiable in the primary circuit. Or it will cause high voltage which is dangerous to personal security.
3. Resistance of current transformer is very low, so that secondary winding of current transformer can be operated as a shortcircuit, when required in test operation. Otherwise, this condition causes high voltage and can be dangerousWe during usage.
4. When selecting a current transformer, it is important to consider the power absorded by the cables connected between the CT secondary terminals and the measuring instrument. The resultant cable burden should be added to the equipment burden, and the total should not exceed the avaiable VA of the CT.
5. P1(K) must face the supply feeder, and P2(L) must face the load. It is also important to ensure that secondary connections are made in accordance with instrument diagrams. The secondary terminals of the CT must NOT be open-circuited on load as dangerously high voltage may be present under these conditions. It is recommended that one side of the secondary winding is earthed.
1. 30% T/T advance , the balance against to the copy B/L
2. Open Letter of Credit
3. Pls confirm the details with us before do the prepayment.
1. Each with Carton
2. 32 pcs in a outter box
3. G/N.W: 26/24kg
4. We can packing as your required
1) VDE, UL, KEMA, CE, CB and BV certificated
2) Monthly Production Capacity -- 100, 000 Pcs
3) All goods examined before delivery by 5 QC staff
4) Prompt Reply Within 24 Hours
5) 200-500 people work environment
6) We have cooperated with IEK (Russia), HIMOINSA (Spain), success (Malaysia), MEMF (Saudi Arabia), VALSI (Mexico), Federal (Turkey), Supco (USA), Tyco Electronics ( UK, USA, Singapore, Australia), Alkhalefah Factory for Metal Industries ( Saudi Arabia)
Dixsen was born in 1992, we are a professional manufacturer focuses on low voltage components like Current and voltage Transformers, Transformers, Meters, MCCBs, MCBs, AC Contactors, Fuse and Bases, Relays and sort of things. We locate in Wenzhou city, Zhejiang province, where is quite close to Shanghai and Ningbo port. A 15000 square meter area is divided into workshop zone and office zone, 430 employees are currently making their great efforts in that area for Dixsen brand.