XLPE Power supply Cable China High Volltage and good quality
USD $0.1 - $99 /Meter
Min.Order:500 Meters
Henan Jinshui Cable Group Co., Ltd.
China cheap price 4 cores xlpe insulated pvc sheath power cable
Aluminum Core XLPE Insulated Cable China High Volltage and good quality
0.6/1kV Cable, Copper Conductor XLPE Insulated PVC Jacketed Power Cable CU/XLPE/PVC IEC 60502-1
3.6 / 6 KV 21 / 35 kV cable Cu/XLPE/STA/PVC steel tape armored cable DIN VDE 0276
XLPE Power Supply Cable China High Voltage and Good Quality
Specifications
3.6/6kv,6/6kV,6/10kV,8.7/10kV, 8.7/15kV,12/20kv, 21/35kV, 26/35kV.GB/T12706-2002 standard(The same as IEC60502).power cable
Electric Cables:
CU Conductor PVC Insulated PVC Sheathed Power Cable
1. The applications: Rated voltage (U0/U) 0.6/1kv 8.7/15KV 26/35kV in transmission & transformation line & for water-proofing purpose .
2. Standards: 60502IEC ISO9001
3. Product features:
1) No necessary to heat up in advance while installing above 0oC.
2) Max. continuous normal operating Temperature: 90oC (PVC Sheathed cable).
3) Max. Permissible temperature at short circuit (5s. at longest): 250oC.
4) Permissible bending radius:
Single core: ≥20(d+D)±5%.
Three-core:≥15(d+D)±5%(D is the actual overall diameter of cable, and d is the actual overall diameter of conductor).
Detailed Description
Our company can produce both flame retardant and non-flame retardant series of XLPE power cable.. Our products can be produced according to our works specifications which are equivalent to GB12706, IEC60502, IEC60332, IEC60754, and its some indexes are superior to standards stated above..
The flame-retardant cable covers all kinds of low-smoke low-halogen, low-smoke halogen free and three classes of A, B, C. We can design and manufacture special XLPE cable according to the other standards require by the customers, such as heavy section cut part conductors, water-resistant, defend termites, defend mouse, and so on..
JKLYJ 10KV |
|
|
|
|
| |
Cross-section Area | Thickness of Insulation | Approx. Overall Dia. | Max. Resistance of Conductor at 20 °C | Min. Breaking Load of conductor | Approx. Weight of Cable | |
mm² | mm | mm | Ω/km | N | kg/km | |
35 | 3.4 | 14.8 | 0.868 | 5177 | 300.8 | |
50 | 3.4 | 16.1 | 0.641 | 7011 | 359.8 | |
70 | 3.4 | 17.8 | 0.443 | 10354 | 441.0 | |
95 | 3.4 | 19.6 | 0.320 | 13727 | 548.0 | |
120 | 3.4 | 21.0 | 0.253 | 17339 | 643.0 | |
150 | 3.4 | 22.6 | 0.206 | 21033 | 753.6 | |
185 | 3.4 | 24.2 | 0.164 | 26732 | 877.3 | |
240 | 3.4 | 26.4 | 0.125 | 34679 | 1061.3 | |
300 | 3.4 | 28.6 | 0.100 | 43349 | 1263.7 |