Steel Wire Armoured Power Cable (Al/PVC/STA/PVC) BS 6346
USD $1 - $10 /Meter
Min.Order:100 Meters
Henan Jinshui Cable Group Co., Ltd.
3.6/6kV Cable--19/36kV Cable Cu/XLPE/AWA/PVC Aluminum Wire Armoured Cable BS 6622
3.6/6kV Cable--19/33kV Cable Cu/XLPE/AWA/PVC(Al/XLPE/AWA/PVC) Cable BS 6622;0.6/1kV Cable
1900/3300V Cable 3 cores Cu/PVC/PVC Cable BS 6346 Cu/PVC/SWA/PVC power cable(Al/PVC/AWA/PVC)
600/1000V Cable-1900/3300V Cable Cu/PVC/SWA/PVC power cable(Al/PVC/AWA/PVC) BS 6346 35kv
600/1000V Cable--1900/3300V Cable Cu/PVC/PVC Steel Tape Armoured Power Cable (Al/PVC/STA/PVC) BS 6346
Detailed Product Description
Specification:
1. The rated voltage (0.6/1kV) of cable should fit for the running of the system.
2. The max running temperature of the conductor of cable is 70, the max temperature of the conductor of cable should less then 150 when short circuit. (less then 5 second)
3. Then min bending diameter should larger then two times of the diameter of the cylinder for cable bending test.
The product is produced against GB12706-91. And the product can be produced against the standard of IEC, DIN, JIS and the standard required by the clients.
3.6/6kV Cable--19/33kV Cable Single Core Cu/XLPE/PVC Copper Wire Screen Cable BS 6622
Detailed Product Description
Product Standard:Our factory produces XLPE cable according to state standard GB12706-91``Rated voltage 35kV and below copper core and aluminium core plastic insulated power cable`` and GB 11017-89``Rated voltage 110kV copper core and aluminium core XLPE insulated power cable``. The GB12706-91 standard is equivalent tointernational standard IEC502-1983``Rated voltage.
Type | Description | Main Application | |
Cu core | Al core | ||
(ZR)YJV or (ZR)YJY | (ZR)YJLV or (ZR)YJLY23 | (Flame retardant) Cu, Al core XLPE insulated, PVC or PE sheathed power cable. | For laying indoor, tunnel, underground and canal. Unable to bear external mechanical pulling force and pressure during laid. |
(ZR)YJV22 or (ZR)YJY23 | (ZR)YJLV22 or (ZR)YJLV23 | (Flame retardant) Cu, Al core XLPE insulated, steel armoured, PVC or PE sheathed power cable. | For laying indoor, tunnel, underground and canal. Able to bear external mechanical pulling force , but unable to bear large pulling force. |
(ZR)YJLV32 or (ZR)YJLV33 | (ZR)YJLV32 or (ZR)YJLV33 | (Flame retardant) Cu, Al core XLPE insulated, fine steel wire armoured, PVC or PE sheathed power cable | For laying in shaft, water under ground and large difference of level, able to bear mechanical pressure and moderate pulling force. |
(ZR)YJLV42 or (ZR)YJLV43 | (ZR)YJLV42 or (ZR)YJLV43 | (Flame retardant) Cu, Al core XLPE insulated, thick steel wire armoured, PVC or PE sheathed power cable | For laying in the water, seabed and large difference of level, able to bear large mechanical pressure and pulling force.. |
1-30kV plastic extruded and wrapped insulated power cable.The GB11017-89 standard adopts international standard IEC840-1988``Rated voltage 30-150kV extruded and wrapped insulated power cable experiment``.
Our factory can also design and produce some XL cable for special requirements according to clients demand.
Property for Use:
1.Max. rated temperature of cable conductor is 90oC.
2.For short circuit (max. sustained time not exceeding 5s), max. temperature of cable conductor not exceeding 250oC.