Nice RT china ups price in pakistan with LCD /LED display
Negotiable /Piece
Min.Order:5 Pieces
Shenzhen Hedwin Technology Co., Ltd.
1.Full digital control
2.6-10KVA Rack online ups
3.By Pass mode
4.0.9 Power Factor
5.High efficiency and reliability
6.True sine wave
0.9PF ,by pass mode, 6-10KVA Rack - Tower online ups Salient Features :
1. Digital Design
Adopted DSP control technology and digital design topology, C UPS can be operated and maintained more conveniently.
2. Reversed Polarity N and L wire Detection Function.
Reversed Polarity of wiring or input protective grounding-wire is abnormal, at this point the indicators will alarm blink cyclically.
3. A Real Green-environmental Protection Power.
The commercial power input factor correction technique is used .Under the Normal mode, UPS achieves real energy-saving by inputting harmonic less than 10% and frequency power factor above 99%.
4. Direct Current Cold Start Function
When battery input voltage in the range of normal voltage. By pressing the ON button ,UPS can start up normally.
5. Alarm High-low Battery Input Voltage Protection Function
UPS alarms in case of the battery input voltage too high or too low. As the battery continuously go up or down out of the normal range, UPS will alarm and stop input or transfer to bypass mode to ensure the battery life and protect user equipment
6. Communication and Monitoring Function
Equipped with standard RS232 interface and intelligent slot. The UPS Operating and electrical parameters can be monitored through standard RS232. Through intelligent slot status interface the intelligent control can be flexibly configured according to different applications to users, for instance ,stem node, network
monitoring, text message
7. Output High- Low Voltage Protection
When UPS output is greater than the output over-voltage protection point or less than the output low-voltage protection point, it will shut off inverter output to bypass and automatically alarm .After all the fault removed, users can restart the machine normally.
Spec of RT6-10K UPS
model Specifications | RT- 6K | RT - 10K | ||||||
Rated power | 6KVA /5.4KW | 10KVA /9KW | ||||||
AC Input | Input system | Single phrase & earth ground | ||||||
Ranged voltage | 110-240 Vac | |||||||
Frequency | 50/60Hz | |||||||
Voltage range | 85~145VAC±5 | |||||||
Frequency range | 50/60±5Hz | |||||||
Voltage range of bypass | 80VAC×(1±5%) - 145VAC×(1±5%) | |||||||
Bettary Input | ||||||||
| Backup Time (half/full loaded) | Half loaded≥10minutes,Full loaded ≥5minutes(standard) | ||||||
Transient rush current in boo-up state | <150% of rated current | |||||||
Battery charger time | Charger to 90% battery capacity in 5 hours(standard) Dependent on the capacity of external batteries(long backup time) | |||||||
AC Output | Output system | Single phrase&earth ground | ||||||
Output voltage | 100/110/120Vac±3%(inverter output) | |||||||
Output frequency | 50/60±5Hz(normal) 50/60Hz±1%(abnormal) | |||||||
Dynamic voltage transient range | <5% | |||||||
Dynamic transient restore | < 60ms | |||||||
Waveform | Sine WaveTHD<3%(linear load) Sine WaveTHD<8%(nonlinear load) | |||||||
Input powerfactor | 0.8 | |||||||
Overload capability | 105-125%≥ 60s,126-150%≥30s The recover point is 90% | |||||||
Input current peak coefficient | 31 | |||||||
Transfer time | < 3 ms | |||||||
Panel indicator system | LED screen+LED indicator,show the status of UPS and operation parameter | |||||||
Communications | RS232(turn to 485),USB port ,RJ45 ,SMNP card independent | |||||||
Alarm Function | AC/DC input under abnormal ,overload condition and inverter problems
| |||||||
Protection Function | AC input or output above or below the range of voltage Overload ,overtemperature and short circuit protection | |||||||
Conduction | Satisfy YD/T983-1998A | |||||||
Radiation | Satisfy YD/T983-1998A | |||||||
Noise Immunity | Satisfy YD/T983-1998A | |||||||
Insulating resistance | > 2MΩ500VDC | |||||||
Insulating strength | 2121VDC(AC input, output to ground,DC input to AC output),without flashover in one minute) | |||||||
Cooling system | wind cooling | |||||||
Noise | <45dB(1M) | |||||||
Working enviroment | Temperature | 10~ +40 | ||||||
humidity | 0~95%,no condensation | |||||||
Altitude | ≤1500m,satisfy GB3859.2-93 | |||||||
Storage enviroment | Inverter temperature | -40~+65 | ||||||
humidity | 0~95%,no condensation |