M-Bus Photoelectric Reading AMR Water Meter
USD $32 - $40 /Piece
Min.Order:500 Pieces
Zhejiang Holley Liyuan Metering Co., Ltd.
M-Bus is especially applied as the Bus structure of public utilities' meters, called as Meter-Bus, short for M-Bus. M-Bus meter bus line pertains to LAN (Local Area Network), is a special network for the same residential building, campus or a certain region within several kilometers that being applied in connecting long distance monitor computer and workstation and the measuring instruments etc.
Product Features:
1>Confirms to EN13757-2 2004 international standard, with a favorable compatibility and openness, meanwhile supports various meter types, such as water/electricity/gas/heat meters etc.
2>Adopt two wire connection mode, enables a long communication distance and bus power supply
3>Non-polar of the transmission line, willfully branch of the network topology, easy network, shooting the problem of meter breakdown and failure of meter reading caused by Bus line misconnection
4>Double power supply modes: Lithium battery and Bus line power supply
5>Real-time reading of the current meter data and monthly data within a year
6>Low power dissipation, quiescent operation current below 5 μ A, guarantee battery of a long service life
Product Advantages:
*M-Bus is the common international standard of consumer instruments, whose topology structure is the Bus line that applies the most common two wires connection and offers/fulfills the function of metering power supply & data communication.
*Non-polar of the Bus line in connecting, willfully wiring construction of the topology network, thus hugely cuts the construction cost & difficulty.
*Bus Line enjoys a perfect compatibility and openness.
*Strong compatibility/generality of its topology structure, allow liner/loop/star or various mixed types.
Technical Data:
Items | Contents |
Water Temperature | 0.1°C-50°C |
Working Pressure | 1.0MPa/1.6MPa |
Head Loss | 0.063MPa |
Max. Permissive Error | maximum permissible error: upper zone(Q2≤Q≤Q4),±2%;low zone(Q1≤Q<Q2), ±5% |
Base Meter Parameters:
Nominal Dia. | Permanent Flow Q3 |
Q3/Q1 |
Q2/Q1 | Min. Reading | Max. Reading |
mm | m³/h | m³ | |||
15 | 2.5 | 80/100 | 1.6 |
0.0001 |
99999 |
20 | 4 | 80/100 | 1.6 | ||
25 | 6.3 | 80/100 | 1.6 |
Installation & Weight:
Nominal Dia. DN(mm) | Length L | Length L1 | Width B | Height H | Connecting Thread
| |
mm | d | D | ||||
15 | 259 | 165 | 89 | 124 | R1/2 | G3/4B |
20 | 300 | 195 | 89 | 124 | R3/4 | G1B |
25 | 344 | 225 | 89 | 130 | R1 | G1 1/4B |