BBZ -LD Series electromagnetic flowmeter
USD $150 - $3,000 /Piece
Min.Order:1 Piece
Henan BBZ Automation Equipment Co., Ltd.
Brief Introduction:
BBZ -LD Series electromagnetic flowmeter is suitable for measuring the volume flow of conductive medium, measuring principle is based on Faraday's Electromagnetic Induction Law. BBZ-LD series electromagnetic flowmeter is mainly composed of the measuring tube, electrodes, excitation coil, iron core and magnetic yoke shell, mainly used to measure the conductivity of liquid and slurry volume flow in closed conduits, including acids, bases, salts and other corrosive liquids. The product is widely used in petroleum, chemical, metallurgy, textile, food, pharmaceutical, paper and other industries as well as environmental protection, municipal administration, water conservancy construction.
Features:
Not affected by fluid density, viscosity, temperature, pressure and electrical conductivity changes;
No impeded flow parts and pressure drop in the measuring tube, lower requirements for the section of straight pipe;
Series nominal diameter of DN25 ~ DN3000, various options for sensor lining and electrode materials;
The converter using a novel excitation mode, low power consumption, zero stability, high accuracy,flow range of up to 1500: 1;
Integrated or separated for sensor and converter;
The converter using16-bit high-performance microprocessors, 2x16LCD display, convenient parameter setting, reliable programming;
Bidirectional flow meter measurement system, built-in three Totalizer for forward total, reverse total and the total amount of the difference; display two-way flow rate with a variety of outputs (current, pulse and digital, HART communication );
The converter using surface mount technology (SMT), a self-test and self-diagnostic function;
Applications:
Factory:
Specifications:
Measuring principle | Electromagnetic | |||||||
Nominal diameter | 15,20,25,32,40,50,65,80,100,125,150,200,250,300,350,400,450,500,600,700,800,900,1000,1200,1400,1600,1800,2000,2200,2400,2600,2800,3000 | |||||||
Maximum flow rate | 15m/s | |||||||
Maximum fluid temperature | Integrated | 70℃ | ||||||
Separated | Neoprene | 80℃;120℃(Noted when ordered) | ||||||
Polyurethane | 80℃ | |||||||
PTFE | 100℃;150℃(Noted when ordered) | |||||||
FEP | ||||||||
PFA | ||||||||
Medium | conductivity liquids | |||||||
Nominal pressure | 4.0MPa | 1.599MPa | 1.0MPa | 0.6MPa | 6.3,10MPa | |||
DN25~DN150 | DNl5~DN600 | DN200~DN1000 | DN700~DN2500 | Customized | ||||
Range ratio | 150:1 | |||||||
Accuracy | DNl5~DN600 | ±0.3% | ||||||
DN700—DN3000 | ±0.5% | |||||||
Fluid conductivity | ≥ 5 U S/cm | |||||||
Electrode material | Stainless steel 0Crl8Nil2M02Ti, Hastelloy C, Hastelloy Β, titanium, tantalum, platinum / iridium alloy, stainless steel coated with tungsten carbide | |||||||
Electrode scraper | DN250—DN3000 | |||||||
Connection flange material | Carbon steel | |||||||
Ground flange material | Stainless 1Crl8Ni9Ti | |||||||
Import protection flange material | DN65—DNl50 | Stainless 1Crl8Ni9Ti | ||||||
DN200~DNl600 | Carbon steel and Stainless 1Crl8Ni9Ti | |||||||
Ambient temperature | Sensors | —25℃~60℃ | ||||||
Converter(Integrated) | —10℃~60℃ | |||||||
Enclosure protection | DNl5 ~ DN3000 separate rubber or polyurethane lining sensor | IP65 or IP68 | ||||||
Other sensors integrated flowmeter and separated converter | IP65 | |||||||
Power supply | 285—265VAC,45—400HzAC 11—40VDC | |||||||
Spacing( Separated) | ≤100m | |||||||
Connection | Flange | |||||||
Liner | PTFE, neoprene, polyurethane, FEP, PFA | |||||||
Ex-proof Grade | Ex ia IIC T6 | |||||||
Protection grade | IP65,IP67,IP68 | |||||||
Operation keys and display | Pushbutton | Four membrane keys can be set to choose all parameters , also can set programming for converter through the PC (RS232); 3-line LCD wide viewing angle, wide temperature range, with backlight display; The first row shows the flow value; The second line shows the flow units; Line 3 shows the percentage of flow rate, forward total, reverse total amount, the difference between the total amount, alarm, flow rate. | ||||||
Magnetic button | 2 magnetic keys are used to select and reset the display parameters, and to set programming for converter through the PC (RS232); 2-line LCD wide viewing angle, wide temperature range, with backlight display: Line 1: Magnetic buttons to select: display flow percentage, the total amount of forward and reverse total amount, the difference between the total amount, alarm, flow rate. Line 2: shows the flow. | |||||||
Output signal | Unidirectional analog output | Full isolation, load ≤600D. (20mA hour); Upper limit: 0-21mA optional, each stall lmA; Lower limit: 0-21mA optional, each stall 1mA; Forward and reverse flow output programming. | ||||||
Bidirectional analog output | Lower limit of 4mA, the other with Unidirectional analog output | |||||||
Bi-directional pulse output | Two outputs corresponding to the forward and reverse flow, frequency 0 ~ 800Hz, the upper limit 1-800Hz optional, each stall IHz; Square wave selected pulse, the selected pulse upper limit 2.5S, each stall 1ms; Passive isolation transistor switching output, can absorb 250mA of current, voltage 35V. | |||||||
Dual Alarm Output | Alarm (programming) high / low flow, empty tube, fault status, forward and reverse flow, analog over range, pulse over range , pulse low-cut, selectable output polarity; Transistor switch outputs with isolation protection, can absorb 250mA of current, voltage 35V. (Pulse output is not isolated) | |||||||
Digital Communications | RS232,RS485,HART |