Microduct 12 Core Singlemode Fiber Optic Cable Most Popular
USD $470 - $480 /Kilometer
Min.Order:2 Kilometers
Sichuan Biwin Imp-Exp Trade Co., Ltd.
Microduct 12 Core Singlemode Fiber Optic Cable
1.Features and Benefits
2.Standards
Unless otherwise specified in this specification, all requirements shall be mainly in accordance with the following standard specifications.
Optical Fibre …... ITU-T G.651,G.652,G.655,G.657
IEC 60793-2-10,IEC 60793-2-50
Optical Cable ……IEC 60794-1-2,IEC 60794-5
3.Technical Parameter
Fiber Count | 2 Fibers | 4 Fibers | 6 Fibers | 8 Fibers | 12 Fibers |
Outer Diameter (mm) | 1.15±0.05 | 1.15±0.05 | 1.35±0.05 | 1.50±0.05 | 1.65±0.05 |
Weight (g/m) | 1.0 | 1.0 | 1.3 | 1.8 | 2.2 |
Min Bend radius (mm) | 50 | 50 | 60 | 80 | 80 |
Temperature | Storage:-30°C~ +60°C Operation:-20°C~ +60°C Installation:-5°C~ +50°C |
4.Testing parameter
Fiber Unit Attenuation
Fiber Type | SM G.652D,G.655,G.657 | MM 62.5/125 | MM 50/125,OM3 |
Attenuation | 0.38dB/km max @1310nm 0.26dB/km max @1550nm | 3.5dB/km max @850nm 1.5dB/km max @1300nm | 3.0dB/km max @850nm 1.0dB/km max @1300nm |
Blowing Test
Fiber Count | 2 Fibers | 4 Fibers | 6 Fibers | 8 Fibers | 12 Fibers |
Test equipment | PLUMETTAZ:UM25, ERICSSON:F, CATWAY:FBT-1.1 | ||||
Standard duct | 5.0/3.5 mm | ||||
Pressure | 7bar / 10bar | ||||
Typical blowing distance | 500m / 1000 m | 500m / 1000m | 500m / 1000m | 500m / 1000m | 500m / 800m |
Typical blowing time | 10 min / 18 min | 10 min / 18 min | 12 min / 18 min | 13 min / 18 min | 15 min / 20 min |
Mechanical Performance
Test | Standard | Parameters | Test Results |
Tension | IEC 60794-1-2-E1 | Load is 1×W | fibre strain ≤0.4% at MAX Additional attenuation ≤0.05dB fibre strain ≤0.05% after test |
Bend | IEC 60794-1-2-E11A | Diam 40mm×3turns 5 cycles at 20°C | Additional attenuation ≤0.05dB,after test |
Crush | IEC 60794-1-2-E3 | 100 N, 60s | Additional attenuation ≤0.05dB,after test |
All optical testing proceeded at 1550 nm |