2015 VCELL 12FT150 Front Terminal gel battery

2015 VCELL 12FT150 Front Terminal gel battery

USD $0.1 - $200 /Piece

Min.Order:25 Pieces

Supply Ability:
100000 Piece / Pieces per Month
Port:
wuhan
Payment Terms:
T/T L/C D/P D/A Credit Card PayPal

Quick Details View All >

Place of Origin:
Hubei, China
Brand Name:
VCELL
Model Number:
12FT150/12FT150-FR
Usage:
UPS
Voltage:
Other, 12v
Sealed Type:
Sealed

Wuhan V-Cell Energy Technology Co., Ltd.

Business Type: Trading Company
Wuhan Hubei China
Main Products: VRLA battery ,Lithium battery ,Solar system ,Spiral Battery ,Aotomotive Battery

Product Details

Specifications

2015 VCELL 12FT150 Front Terminal battery
1.Low self-discharge
nnection easily,less space occupied
3.Near to 0 loss rate

2015 VCELL 12FT150 Front Terminal battery

Product Description

 Specification

 

NORMINAL VOLTAGE       :12V
NORMINAL CAPACITY       :150Ah at 8hr.rate to 1.75 v/cell
DIMENSIONS
  
   TOTAL HEIGHT              :288mm(11.34inches)

   CONTAINER HEIGHT     :288mm(11.34inches)
  
   LENGTH                        :551mm(21.69inches)

   WIDTH                          :110mm(4.33inches)
WEIGHT                           :APPRO×48Kg(105.82lbs)
CONTAINER MATERIAL     :UL94HB ABS
                                       :UL94V-0ABS
INTERNAL RESISTANCE(25°C, 77°F):-4.0m
DISCHARGE CAPACITY UNDER DIFFERENT TEMPERATURES
   40°C                 :-102%
   25°C                 :-100%
   0°C                   :-85%

 Characteristics

 

CAPACITY 25°C/77°F
   20hr at 7.8A                               :106Ah
   10hr at15.00A                            :150Ah
   3hr at 38.7A                               :116Ah
   1hr at 93.00A                             :93Ah
CHARGING VOLTAGE(25°C, 77°F)
STANDBY USE                                  :13.65V±0.15V
CYCLE USE                                      :14.7V±0.3V
MAX DISCHARGE CURRENT              :500A(5 sec)
MAX CHARGING CURRENT                :37.5A
SELF-DISCHARGE RESIDUAL CAPACITY(25°C, 77°F)
   AFTER 3 MONTHS                         :-90%
   AFTER 6 MONTHS                         :-82%
   AFTER 12MONTHS                         :-70%
Cycle Life (25°C, 77°F)
         30%DOD                         :>1800TIMES
         50%DOD                         :>800TIMES
         100%DOD                       :>350TIMES

 

 Odering Guide

 

SeriesCapacityOpinionsTerminal Type
12FT150AHFR(Flame Retardant)RT-02
~(Non Flame Retardant)

 

 

 

 Features and Benefits:

10Year Design Life

*Flame Retardant Poly Propylene Case and Cover

 Impact resistance, self-extinguishing material with standard Underwriters Laboratories(UL) 94V rating

*Tank Formed Plate Construction

  100% capacity on shipment

   Plate consistency and matching dependable performance

* Copper Threaded Insert Post

   High conductivity

   Retains required torque values and allows for easy installation

*Epoxy Post Seal

   Elimination of acid egress for trouble-free service life

* Ceramic Disc Flame Arrestor

  Prevent any errant spark or flames from entering the battery

*Transportation

  Non-hazardous for air/sea/rail/road transportation

*Applicable Standards

  UL Recognized

  UL 1778 4th edition -UPS equipment certification

  IEC 60896 Part 21-VRLA methods of testing

  IEC 60896 Part 22-VRLA requirements

  BS 6290 Part 4-Specifications for VRLA classification

*VCELL  Manufacturing

  ISO 9001 Quality Management System

  ISO 14001Environmental Management System

  OHSAS 18001 Workplace Safety & Health

 

 

 

 

Constant Power Discharge Rating - Watts per Cell @ 77°F(25°C) Operating Time to End Point Voltage(in minutes)
End Point
Volts/Cell
1.03.05.010.015.030.060.0180.0300.0600.01200.0
1.61290.0955.0780.0630.0547.0302.0201.084.755.329.916.5
1.71210.0900.0735.0600.0527.0300.0198.084.254.929.916.5
1.71155.0860.0704.0565.0508.0299.0195.083.654.529.916.5
1.81095.0820.0675.0540.0489.0298.0193.083.154.229.816.5
1.81060.0795.0655.0525.0469.0297.0191.082.554.029.816.5
Constant Current Discharge Rating - Amperes @ 77°F(25°C) Operating Time to End Point Voltage(in minutes)
End Point
Volts/Cell
135101530601803006001200
1.67605454383462891721084528.715.68.6
1.656905054083252761691064428.515.68.6
1.76454753853062631661044328.315.58.5
1.756054483652902521621024228.215.58.5
1.84564283502802381591004228.115.48.5

 

 

Charge Characteristics&Discharge Characterics

 

2015 VCELL 12FT150 Front Terminal gel battery2015 VCELL 12FT150 Front Terminal gel battery

 

Packaging & Shipping

 Packing Details:1pc/ carton box packing, can pack on client's demand

 Delivert Details:30~ 45days upon receipt of the offical order.

 

Our Services

 

Minimum Order Quantity : 25 Piece/Pieces
FOB Price: USD 0.1~200/ Piece
Port :Wuhan,China
Supply  Ability: 100000 Piece/Pieces per month
Payment terms:   L/C,D/A,D/P,T/T,Western Union,MoneyGram
Packaging Details: cartons
Delivery detail: 30~45 days upon receipt of official order

 

Company Information

  Wuhan V-cell Energy Technology Co.,LTD. was established in 2005 and specializes in the research, development, manufacture and sale of Vcell brand batteries. The full battery range includes VRLA ( Valved Regulated Lead Acid ) batteries, Car batteries, Primary lithium batteries and Lithium-ion batteries, which are widely used in telecom, emergency lighting, alarm systems, security, medical field, cordless devices and wheelchair industries. Our experience and technical excellence are acclaimed in China and world telecom industry.

 

 

 

Contact Supplier

Ms. Sally Tao manager Chat Now
Telephone
86-27-83634766,13607147217
Mobile
13907184602
Fax
86-27-83639466
Address
NO.1805, BAOFENGSHIDAI PLAZA, JIEFANG AVE., WUHAN, HUBEI, CHINA Wuhan,Hubei

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Batteries > Storage Batteries
Categories
Hi~