Low noise Hengtong Dust Exhausting Centrifugal Blower Fan
USD $450 - $899 /Set
Min.Order:1 Set
Henan Hengtong Blower Co., Ltd.
Low noise Hengtong Dust Exhausting Centrifugal Blower Fan
Hengtong Blower products in each big industry were used as key equipment, among dust removal centrifugal fan, boiler centrifugal fan, cement plant dedicated centrifugal fan,air centrifugal fan , gas delivery centrifugal fan high temperature centrifugal fan, environmental protect centrifugal fan etc were used in industrial and civil fields.
Application
Air Pollution Control | Hengtong blower high quality pre-designed and custom heavy duty fans provide proper air quality and volume control, in order to meet the needs of air pollution control system. Our fans are designed to collect the contaminated air and either contain or remove the contaminants from the environment. Hengtong blower’s high efficiency and customizable air treatment products meet the latest requirements for air pollution control field. |
Boiler System | According to different applications, boiler system are used for generating steam and electric energy in many different industries. boiler system needs forced draft fans to offer combustion air ,at the same time, induced draft fan remove products of combustion and maintain the required draft. over-fire air fan, primary air and FGR fan are used to circulate gases to different parts of the system. Hengtong blower is a leading provider of pre-engineering and heavy custom duty fans for boiler system. |
Dust Collection | Hengtong blower is a leading provider of fans and blowers for dust collection applications, our fans are used to supply dirty corrosive air into the system, and exhausting clean air out of the system. whether it is sawdust,metal scraps,or welding smoke, we design and manufacture various pre-engineered and custom heavy duty fans to capture the particles exhausted into the air. |
Containment | According to different applications, the control and containment of harmful fume is necessary for a safety working environment, particles fumes and odors exhausted into the air needs to be captured and controlled directly from the source, Hengtong blower designs fans dealing both clean and dirty air to keep a safe working environment. |
Transportation | The transportation industry requires high quality durable fans for military, construction and mining purposes as well as locomotive and aviation systems. Hengtong Blower’s pre-engineered and custom heavy duty fans are designed and manufactured for braking schemes, exhaust systems, and general ventilation applications. Our fans are constructed with spark resistant materials and can withstand the highest temperatures for exceptional durability even in the most extreme environments. |
Hengtong blower custom-engineered centrifugal fans are designed specifically for each contract which allows us to apply a combination of experience, advanced design techniques and a knowledge of the operating conditions to select the optimum fan in terms of capital cost, running cost, maintainability and reliability. A wide range of options are available in terms of drive arrangement, output control, layout and ancillary equipment, to give maximum flexibility to the plant designer.
Recommended parts
Low noise HengTong Dust Exhausting Centrifugal Blower Fan:
Casing: Rugged enclosure design, selection of appropriate electrode for welding high-strength , ensure that housing more durable.
Impeller :Impeller annealed completely eliminate welding stress generated when the structure to ensure that the shape of the impeller does not occur creep and cracks.
Air inlet: Convergence can be a good design to reduce wind resistance, and to be able to get better gas inlet angle when entering the impeller wheel, can effectively improve the operating efficiency of the fan.
Overall support:Overall support is your installation is very simple and easy operation.
Motor:General motor, high voltage, frequency conversion motor or custom is appropriate for your system.
Optional components Flow Process Fan driven by motor, drive the impeller rotation, the gas along the air inlet get into the impeller, as a result of the action of the impeller, the gas gain energy, pressure and kinetic energy increased, the impeller gas out of the volute impeller junior people after work, leave is the role of volute impeller gas concentration of diversion, and parts of the gas kinetic energy into the static pressure, and then send the gas from the outlet of the spiral case, when the gas enough energy to overcome the resistance of pipelines and gas can be transported to high or the distance.
Technical Parameters
Application | Temperature | Normal temperature Air | |||
Hot Air | |||||
Air composition | Clean air | ||||
Dusty air | |||||
Corrosive gas | |||||
Combustible gas | |||||
Powder materials | |||||
Light particle materials | |||||
Performance | Impeller diameter | 400 | ~ | 3200 | mm |
Speed of mainshaft | 730 | ~ | 2550 | rpm | |
Pressure range | 402 | ~ | 5358 | Pa | |
3 | ~ | 40 | mmHg | ||
41 | ~ | 5467 | mmH2O | ||
Flow range | 5508 | ~ | 119491 | m3/h | |
9363 | ~ | 2013112 | CFM |
Installation Service
There are three methods for our installation: Production process Quality Assurance
Hengtong's Quality Control programe is supported by a comprehensive Quality Management System (ISO 9001:2000), deviced at the time of inception andcontinuously upgraded. We have in place highly mechanised testing facilities, with procedures laid out to the requirement standards. The test facilities in place permit the flawless testing of the complete range of our products.
customer visitting
our blowers are exported to Vietnam, Libya, the Philippines, Albania, Romania, Pakistan, India, EU and other countries and regions, which has won the domestic and foreign customers and several design institutes broad trust and praise. We will appreciate it a lot if you can offer us your product performance requirement and operation environment for the ventilation jet fan of you need,so that we can customize optimal product to meet your every requirement.
Air volume/air flow |
| m3/h |
Total pressure or static pressure |
| Pa |
Medium temperature |
| ℃ |
Voltage |
| v |
Frequency |
| Hz |
Altitude of operation place |
| m |
If you are interested in our Low noise HengTong Dust Exhausting Centrifugal Blower Fan, Please don't hesitate to contact me !