High energy efficiency boilers hydronic blower
USD $1,000 - $5,000 /Set
Min.Order:1 Set
Henan Hengtong Blower Co., Ltd.
High energy efficiency boilers hydronic blower
Welcome To Henan Hengtong Blower CO.,LTD
Hengtong Blower produces in each big industries used as key equipment, among dust removal blower, boiler blower, cement plant dedicated blower, boilers hydronic blower, environmental protect blower etc were used in industrial and civil fields.
Application
Boiler System | According to different applications, boiler system are used for generating steam and electric energy in many different industries. boiler system needs forced draft fans to offer combustion air ,at the same time, induced draft fan remove products of combustion and maintain the required draft. over-fire air fan, primary air and FGR fan are used to circulate gases to different parts of the system. Hengtong blower is a leading provider of pre-engineering and heavy custom boilers hydronic blowers for boiler system. |
Burner System | Hengtong is a leading provider of pre-engineering and heavy custom duty fans for burner system applications, burner system are widely used for heating and drying throughout various industries. our fans and blowers are constructed with abilities to supply long lasting quality and consistent airflow for high pressure and combustion air systems |
Forced Draft | Forced draft fans typically provide positive pressure and to control pressure inside specific application. Specific pressures are maintained and controlled by both the forced draft fans and inlet or outlet dampers. Hengtong blowers are the most commonly used boiler systems, forced their way into the air so that the boiler efficiency. |
Aeration | Aeration system usually involve the use of a fan or a blower to inject and move air through solids or liquids, various materials needs ventilations due to the changing environment ,hengtong blower fans are utilized in aeration system to supply air and remove wasted compounds in wasted-water system. our boilers hydronic blowers also provide moist and temperature control instorege and compositing applications. |
Pneumatic Conveying | Hengtong blower provide a wide range of lines of air handing equipment for conveying powder and bulk solids. the bulk density of the materials such as food or metal must be determined with the purpose to convey materials by airflow, our fans are designed to produce high velocity air to carry materials from processing stage to the collection stage. fans and blowers are also used to conveying ,so as to provide extra cooling and aeration to the materials if needed. |
Mian produce
Hengtong blower custom-engineered boilers hydronic blowers are designed specifically for each contract which allows us to apply a combination of experience, advanced design techniques and a knowledge of the operating conditions to select the optimum fan in terms of capital cost, running cost, maintainability and reliability. A wide range of options are available in terms of drive arrangement, output control, layout and ancillary equipment, to give maximum flexibility to the plant designer.
Recommended parts
Casing: Rugged enclosure design, selection of appropriate electrode for welding high-strength , ensure that housing more durable.
Impeller :Impeller annealed completely eliminate welding stress generated when the structure to ensure that the shape of the impeller does not occur creep and cracks.
Air inlet: Convergence can be a good design to reduce wind resistance, and to be able to get better gas inlet angle when entering the impeller wheel, can effectively improve the operating efficiency of the fan.
Overall support:Overall support is your installation is very simple and easy operation
Motor:General motor, high voltage, frequency conversion motor or custom is appropriate for your system
Belt pulley: The structure is compact save a space ,differential transmission.
Optional components
Our Principle
Boilers hydronic blower driven by motor, drive the impeller rotation, the gas along the air inlet get into the impeller, as a result of the action of the impeller, the gas gain energy, pressure and kinetic energy increased, the impeller gas out of the volute impeller junior people after work, leave is the role of volute impeller gas concentration of diversion, and parts of the gas kinetic energy into the static pressure, and then send the gas from the outlet of the spiral case, when the gas enough energy to overcome the resistance of pipelines and gas can be transported to high or the distance.
Technical Parameters
Application | Temperature | Normal temperature Air | |||
Hot Air | |||||
Air composition | Clean air | ||||
Dusty air | |||||
Corrosive gas | |||||
Combustible gas | |||||
Powder materials | |||||
Light particle materials | |||||
Performance | Impeller diameter | 400 | ~ | 2000 | mm |
Speed of mainshaft | 960 | ~ | 4000 | rpm | |
Pressure range | 251 | ~ | 4500 | Pa | |
1 | ~ | 33 | mmHg | ||
25 | ~ | 459 | mmH2O | ||
Flow range | 220 | ~ | 221730 | m3/h | |
373 | ~ | 376899 | CFM |
Production process
Installation service
There are three methods for our installation service:
Quality Assurance:
Hengtong's Quality Control programe is backed by a comprehensive Quality
Management System (ISO 9001:2000), deviced at the time of inception and
continuously upgraded. We have in place highly mechanised testing facilities, with procedures laid out to the requirement standards. The test facilities in
place permit the flawless testing of the complete range of our products.
customer visitting
our blower export to Vietnam, Libya, the Philippines, Albania, Romania, Pakistan, India, EU and other countries and regions, which has won the domestic and foreign customers and several design institutes broad trust and praise.
We will appreciate it a lot if you can offer us your product performance requirement and operation environment for the boilers hydronic blower of you need,so that we can customize optimal product to meet your every requirement.
Air volume/air flow |
| m3/h |
Total pressure or static pressure |
| Pa |
Medium temperature |
| ℃ |
Voltage |
| v |
Frequency |
| Hz |
Altitude of operation place |
| m |
If you are interested in our boilers hydronic blower, Please don't hesitate to visit our website.
htblower.en.china.cn
We will give you a favorable price. .