bare AAAC AAC ACSR ACS AACS ACAR Conductor for overhead line
USD $0.1 - $5 /Meter
Min.Order:1000 Meters
Zhengzhou Hongda Cable Co., Ltd.
bare AAAC AAC ACSR ACS AACS ACAR Conductor
AAAC AAC ACSR ACS AACS ACAR bare Conductor for overhead aerial use
1 All Aluminum Alloy Conductor AAAC Conductor
Standard: ASTM B398, ASTM B399, BS 3242 DIN 48201, CSA C49, NFC 34-125
2 Applications & Advantages
Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a highstrength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.
3 Specifications
AAAC bare conductor meets or exceeds the following ASTM specifications:
B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes
B-399 Concentric-Lay-Stranded 6201 J81 Aluminum Alloy Conductors
4 Construction
Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay-stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6201 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core.
The DC resistance at 20"C of the 6201-T81 conductors and of the standard ACSR of the same diameter are approximately the same. Conductors of the 6201 J81 alloys are harder and, therefore, have a greater resistance to abrasion than conductors of 1350-H 19 grade aluminum.
5 CONDUCTOR TECHNICALS EXAMPLE
CODE WORD | Size (KCM) |
Strand | Dia. ( Inches ) | Cross Section Area ( Sq.in) | Weight Per 1000ft ( lbs )
| Rated Strength ( lbs )
| Resistance Ohms/1000ft | Current Rating ( Amps ) |
Size | ACSR with Equiv. Diam. Stranding ( Al/St) | Approx. ECCond. With Equiv. Resistance | |||
Indiv. Wires | Complete Cable | |||||||||||||
DC.@ 20°C | AC@ 75°C | |||||||||||||
Akron | 30.58 | 7 | .0661 | .198 | .0240 | 28.7 | 1,110 | .659 | .785 | 107 | 6 | 6/1 | 6 | |
Alton | 48.69 | 7 | .0834 | .250 | .0382 | 45.7 | 1,760 | .414 | .493 | 143 | 4 | 6/1 | 4 | |
Ames | 77.47 | 7 | .1052 | .316 | .0608 | 72.7 | 2,800 | .260 | .310 | 191 | 2 | 6/1 | 2 | |
Azusa | 123.3 | 7 | .1327 | .398 | .0968 | 115.7 | 4,460 | .163 | .195 | 256 | 1/0 | 6/1 | 1/0 | |
Welcome to send us request on AAAC AAC ACSR ACS AACS ACAR bare Conductor