Bare Aluminium Alloy Conductor ASTM Standard AAAC Conductor
Bare Aluminium Alloy Conductor ASTM Standard AAAC Conductor
Bare Aluminium Alloy Conductor ASTM Standard AAAC Conductor

Bare Aluminium Alloy Conductor ASTM Standard AAAC Conductor

USD $0.2 - $10 /Kilometer

Min.Order:1 Kilometer

Supply Ability:
2000 Kilometer / Kilometers per Month
Port:
Qingdao or Shanghai or Shenzhen
Payment Terms:
T/T Credit Card

Quick Details View All >

Place of Origin:
Henan, China
Brand Name:
Hongda
Model Number:
AAAC Conductor
Type:
Low Voltage
Application:
Other, Overhead, Overhead Power Transmission
Conductor Material:
Other, AAAC

Zhengzhou Hongda Cable Co., Ltd.

Business Type: Manufacturer,Trading Company
Zhengzhou Henan China
Main Products: ABC Cable ,PVC Cable ,AAC\ ACSR ,XLPE Cable ,electric wire

Product Details

Bare Aluminium Alloy Conductor ASTM Standard AAAC Conductor

 

Product Description

 

1). Standard:

 BS EN50182, ASTM B399, DIN48201 part6, BS 3242

 

2). Specification:

 AAAC are composed by bare concentric-lay-stranded aluminum alloy wires.

 

3). Application:

AAAC are used in overhead electric power transmission and distribution lines.

 

4).Construction:
Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay-stranded, similar in construction and appearance to 1350 grade aluminum conductors.

Standard 6201 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core.

The DC resistance at 20"C of the 6201-T81 conductors and of the standard ACSR of the same diameter are approximately the same. Conductors of the 6201 J81 alloys are harder and, therefore, have a greater resistance to abrasion than conductors of 1350-H 19 grade aluminum 

 

5).Packing: Strong Wooden Drum or Iron Wooden Drum.

 

The data sheets below show the most common standards, British standard and IEC standard.
IEC Sizes IEC 61089

Code Number

Stranding&wire diameter

Approx Overall diameter

Nominal

Approx.

Breaking Load

DC Resistance at 20

area

Weight

mm

mm

mm 2

Kg/km

KN

Ohm/km

16

7/1.83

5.49

18.4

50.4

5.43

1.7896

25

7/2.29

6.86

28.8

78.7

8.49

1.1453

40

7/2.89

8.68

46

125.9

13.58

0.7158

63

7/3.63

10.9

72.5

198.3

21.39

0.4545

100

19/2.78

13.9

115

316.3

33.95

0.2877

125

19/3.10

15.5

144

395.4

42.44

0.2302

160

19/3.51

17.6

184

506.1

54.32

0.1798

200

19/3.93

19.6

230

632.7

67.91

0.1439

250

19/4.39

22

288

790.8

84.88

0.1151

315

37/3.53

24.7

363

998.9

106.95

0.0916

400

37/3.98

27.9

460

1268.4

135.81

0.0721

450

37/4.22

29.6

518

1426.9

152.79

0.0641

500

37/4.45

31.2

575

1585.5

169.76

0.0577

560

61/3.67

33

645

1778.4

190.14

0.0516

630

61/3.89

35

725

2000.7

213.9

0.0458

710

61/4.13

37.2

817

2254.8

241.07

0.0407

800

61/4.38

39.5

921

2540.6

271.62

0.0361

900

91/3.81

41.8

1036

2861.1

305.58

0.0321

1000

91/4.01

44.1

1151

3179

339.53

0.0289

1120

91/4.25

46.7

1289

3560.5

380.27

0.0258

1250

91/4.49

49.4

1439

3973.7

424.41

0.0231

 

 

Welcome to your enquiry!!!!

 

SPECIFICATIONS

 AAAC-6201 bare conductor meets or exceeds the following ASTM specifications:

• B-398 Aluminum-Alloy 6201-T81 Wire for Electrical Purposes.

• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.

 

CONSTRUCTION

Aluminum alloy 6201 wires, concentrically stranded.

 

Code

Size

Stranding

Diameter

Cross sectional

Weight

Rated Strength

resistance

Allowable Amp

Ind. Wire

Cable

DC@ 20°C

AC @30°C

Kcmil

No.

mm

mm

Sq.ins

Lbs/1000feet

lbs

Ohm/km

Ohm/km

A

Akron

30.58

7

0.0661

0.198

0.0240

28.5

1110

.659

.785

107

Alton

48.69

7

0.0834

0.250

0.0382

45.4

1760

.414

.493

143

Ames

77.47

7

0.1052

0.316

0.0608

72.2

2800

.260

.310

191

Azusa

123.3

7

0.1327

0.398

0.0968

115.0

4460

.163

.195

256

Anaheim

155.4

7

0.1490

0.447

0.1221

144.9

5390

.130

.154

296

Amherst

195.7

7

0.1672

0.502

0.1537

182.5

6790

.103

.123

342

Alliance

246.9

7

0.1878

0.563

0.1939

230.2

8560

.0816

.0973

395

Butte

312.8

19

0.1283

0.642

0.2456

291.7

11000

.0644

.0769

460

Canton

394.5

19

0.1441

0.720

0.3099

367.9

13300

.0511

.0610

532

Cairo

465.4

19

0.1565

0.783

0.3655

434.0

15600

.0433

.0518

590

Darien

559.5

19

0.1716

0.858

0.4394

521.7

18800

.0360

.0431

663

Elgin

652.4

19

0.1853

0.927

0.5124

608.4

21900

.0309

.0371

729

Flint

740.8

37

0.1415

0.990

0.5818

690.8

24400

.0272

.0327

790

Flint

740.8

37

0.1415

0.990

0.5818

690.8

24400

.0272

.0327

790

Amp based on 75°C conductor temperature, 25°C ambient temperature, 2 ft/sec. wind in sun, emissivity 0.5, 52.5% conductivity.

 

Bare Aluminium Alloy Conductor ASTM Standard AAAC ConductorBare Aluminium Alloy Conductor ASTM Standard AAAC Conductor

Bare Aluminium Alloy Conductor ASTM Standard AAAC Conductor

Packaging & Shipping

 Bare Aluminium Alloy Conductor ASTM Standard AAAC Conductor

Bare Aluminium Alloy Conductor ASTM Standard AAAC Conductor

 

Company Information

 Bare Aluminium Alloy Conductor ASTM Standard AAAC Conductor

Bare Aluminium Alloy Conductor ASTM Standard AAAC Conductor

Contact Supplier

Mr. Hong Li General manager Chat Now
Telephone
86-371-60975619
Mobile
13783451632
Fax
86-371-60975616
Address
Houzai industrial park, erqi zone Zhengzhou,Henan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Wires, Cables & Cable Assemblies > Electric Cable
Categories