Universal AC input server power supply 200w
Negotiable /Unit
Min.Order:200 Units
Xiamen Evada Electronics Co., Ltd.
Universal AC input server power supply 200w
Features : |
Universal AC input / Full range (up to 264VAC) |
Protections: Short circuit / Overload / Over voltage |
Built-in active PFC function |
Cooling by free air convection |
Suitable for LED lighting and moving sign applications |
IP65 / IP67 design for indoor or outdoor installations |
Damp / wet location outdoor application |
Compliance to worldwide safety regulations for lighting |
3 years warranty |
SPECIFICATION
MODEL | CUF-200-600-FA1 | |||||||||
OUTPUT | DC VOLTAGE | 33V | ||||||||
CONSTANT CURRENT REGION | 27V-33V | |||||||||
RATED CURRENT | 6A | |||||||||
RATED POWER | 200W | |||||||||
RIPPLE & NOISE (max.) | 500mVp-p | |||||||||
LINE REGULATION | ±5% | |||||||||
LOAD REGULATION | ±5% | |||||||||
SETUP, RISE TIME | 3000ms, 80ms at full load 230VAC /115VAC | |||||||||
HOLD UP TIME (Typ.) | 50ms / 230VAC 16ms / 115VAC at full load | |||||||||
INPUT | VOLTAGE RANGE | 100-264VAC | ||||||||
FREQUENCY RANGE | 47-63Hz | |||||||||
POWER FACTOR | PF≥0.99/115VAC PF≥0.97/230VAC | |||||||||
EFFICIENCY (Typ.230Vac/50Hz) | ≥88% | |||||||||
AC CURRENT | 2.290A / 115VAC 0.706A / 230VAC | |||||||||
INRUSH CURRENT(max.) | COLD START 5A/230VAC | |||||||||
LEAKAGE CURRENT | <5mA / 240VAC | |||||||||
PROTECTION | OVER CURRENT (Typ.) | 95 - 108% | ||||||||
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||||||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 36V-38V | |||||||||
Protection type : Constant voltage limiting | ||||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +55℃ @ full load ; +70℃ @ 60% load | ||||||||
WORKING HUMIDITY | 20-95% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40~ +80℃, 10 ~95% RH | |||||||||
TEMP. COEFFICIENT | ±0.03%/℃(0-50℃) | |||||||||
VIBRATION | 10 - 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||||
SAFETY & EMC | SAFETY STANDARDS | UL1012 ; EN61347-1, EN61347-2-13 independent ; UL60950-1, TUV EN60950-1 (TBD) | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC | |||||||||
SOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 ℃/ 70% RH | |||||||||
EMI CONDUCTION & RADIATION | Compliance to EN55015, EN55022 (CISPR22) Class B | |||||||||
HARMONIC CURRENT | Compliance to EN61000-3-2 Class C (≥75% load) ; EN61000-3-3 | |||||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, light industry level (surge 4KV), criteria A | |||||||||
OTHERS | MTBF | 30Khours. | ||||||||
DIMENSION | L225*W69*H39.2mm | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. | |||||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||||||
3. Constant current operation region is within 75% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. | ||||||||||
4. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18. |
Mechanical Specification