YD300 Portable Water Hardness Meter
USD $337 - $378 /Set
Min.Order:1 Set
Shanghai Yanhe Instrument Equipment Co., Ltd.
Portable meter for measurement of water hardness by electrode measurement method, suited in field and on site.
Portable meter for measurement of water hardness (the total concentration of calcium ion and magnesium ion). |
Electrode adopts model 601-F water hardness combination electrode with patent structure. It consists of measurement electrode, reference electrode and temperature probe. Replaceable measuring head, steady potential, fast response, easy to use. |
Meter adopts intelligent chip design, automatic calibration, automatic temperature compensation, time display, data storage, low voltage display, etc. |
Ability to switch among eight units: mmol/L, mg/L (CaCO3), mg/L (CaO), mmol/L (Boiler), mg/L (Ca). Three options of three units : ºfH(France),ºdH (Germany)and ºeH(UK)from WH-Link communication software. |
Equipped with B1,B2 and B3 calibration solution. |
IP57 waterproof rating, equipped with portable case, calibration solution and other accessories. |
Water Hardness | Measuring range Resolution Accuracy Temp. compensation Calibration Solution Calibration Mode | (0 ~ 10)mmol/L; (0 ~ 401)mg/L(Ca); (0 ~ 1000)mg/L(CaCO3); (0 ~ 100)ºfH(France Degree); (0 ~ 561)mg/L(CaO); (0 ~ 56)ºdH(German Degree); (0 ~ 20)mmol/L(Boiler); (0 ~ 70)ºeH (England Degree). 0.01 and 0.1 water hardness units ±5% FS (5 ~ 50)℃((automatic)) B1 Calibration Solution — 2.00×10-2 mmol/L B2 Calibration Solution — 2.00×10-1 mmol/L B3 Calibration Solution — 2.00 mmol/L (B3Calibration Solution also can be used for the soaking solution of electrode) (a)B1/B2 Calibration—using B1 and B2 Calibration Solution,suitable for < 2.00×10-2 mmol/L low concentration water quality,for example, boiler water. (b)Calibration—using B2 and B3 Calibration Solution,suitable forgeneral water quality. |
Temperature | Measuring range Resolution Accuracy | 0 ~ 60℃ 0.1℃ ±0.5℃ |
Other Technical Parameter | Data storage Content Storage
Power Dimension and weight Quality & safecertificate | 99 groups serial number of measuring value, measuring value, units, temperature, ATC or MTC, date, time and calibration way. Two AA cells(1.5V×2) Meter:(65×120×31)mm/180g; Carry Case: (255×210×50)mm/790g IISO9001:2000 and CE |
working conditions | Ambient temperature ambient humidity | (5~35)℃ ≤85%RH |
1. Model YD300 water hardness meter | 1set |
2.Model 601-S water hardness electrode( With two measruing heads and one screw plug ) | 1pc |
3. AA cell (1.5V ) | 2pcs (included) |
4.100mL hardness calibration solution ( B1, B2 and B3 ) | 1btl/each |
5.20mL test cup | 6pcs |
6. Test cup pedestal | 1pc |
7.Carring case | 1pc |
8. Operation manual | 1 set |
Accessory Category | Description | Specification |
Water hardness electrode | 601-S water hardness electrode | Suited for measurement of total concentration of calcium ion and magnesium ion, match YD300 meter, 8 pin connector |
Water hardness calibration solution | Water hardness calibration solution B1 | 2.00×10-2 mmol/L,500mL/250mL/100mL(bottle) |
Water hardness calibration solution B2 | 2.00×10-1 mmol/L,500mL/250mL/100mL(bottle) | |
Water hardness calibration solution B3 | 2.00 mmol/L,500mL/250mL/100mL(bottle) | |
| Plasic test cup | Specification:20mL |
Test cup base | Place test cup on the base |