Bante900P Portable Multi-parameter Water Quality analyzer pH meter CE ISO Certified Quality Choice
USD $520 - $560 /Set
Min.Order:1 Set
Shanghai Yanhe Instrument Equipment Co., Ltd.
Multiparameter meter, 15 function parameters can be set, 8 measurement modes included.
pH Mode:
• High accuracy portable multiparameter water quality meter is equipped with a large backlit
LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.
ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurement modes provide accurate ORP readings.
Ion Mode:
• 2 to 5 points calibration including the eight concentration calibration points can be selected.
• Automatically recognize ion selective electrodes, does not need to specify type of ion.
• Direct ion concentration readout simplifies the elaborate measurement process.
• Selectable multiple concentration units including the ppm, mg/L and mol/L.
Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constants (0.1/1/10), normalization temperatures (20/25°C), TDS conversion
factors, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy.
Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 15 parameters, including the calibration points, resolutions,
stability conditions, measurement units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
• Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use
the meter smoothly.
Model | Bante900P | |
pH | ||
Range | -2.000~20.000pH | |
Accuracy | ±0.002pH | |
Resolution | 0.1, 0.01, 0.001pH | |
Calibration Points | 1 to 5 points, USA, NIST, DIN Standards | |
Temperature Compensation | 0~100°C, 32~212°F, Manual or Automatic | |
mV | ||
Range | -1999.9~1999.9mV | |
Accuracy | ±0.2mV | |
Resolution | 0.1, 1mV | |
Calibration Points | 1 point (Only for Relative mV mode) | |
Calibration Range | ±200mV | |
Ion | ||
Range | 0.001~19999ppm, mg/L, mol/L (Depending on range of ISE) | |
Accuracy | ±0.5% F.S (Monovalent), ±1% F.S (Divalent) | |
Resolution | 0.001, 0.01, 0.1, 1 | |
Calibration Points | 2 to 5 points | |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L | |
Conductivity | ||
Range | 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm | |
Accuracy | ±0.5% F.S | |
Calibration Points | 1 to 5 points | |
Calibration Solutions | 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm | |
Temperature Compensation | 0~100°C, 32~212°F, Manual or Automatic | |
Temperature Coefficient | 0.0~10.0%/°C | |
Compensation Modes | Linear or Pure Water | |
Cell Constant | K=0.1, 1, 10 | |
Normalization Temperature | 20 or 25°C | |
TDS | ||
Range | 0~10ppt (Max. 20ppt, depending on factor setting) | |
Accuracy | ±1% F.S | |
TDS Factor | 0.1~1.0 (Default 0.5) | |
Salinity | ||
Range | 0~10ppt (Max. 80ppt) | |
Accuracy | ±1% F.S | |
Measurement Modes | Seawater or Practical Salinity | |
Resistivity | ||
Range | 0~100MΩ | |
Accuracy | ±1% F.S | |
Resolution | 0.01, 0.1, 1 | |
Dissolved Oxygen | ||
Range | 0.00~20.00mg/L (or ppm) | |
Accuracy | ±0.2mg/L | |
Resolution | 0.01mg/L | |
Calibration Points | 1 or 2 points | |
Temperature Compensation | 0~50°C, 32~122°F | |
Pressure Correction | 60.0~112.5kPa, 450~850mmHg | |
Salinity Correction | 0~50g/L | |
% Saturation of Oxygen | ||
Range | 0.0~200.0% | |
Accuracy | ±2.0% F.S | |
Resolution | 0.1% | |
Temperature | ||
Range | 0~105°C, 32~221°F | |
Accuracy | ±0.5°C, ±0.9°F | |
Resolution | 0.1°C | |
Calibration Points | 1 point | |
Calibration Range | Measured value ±10°C | |
Others | ||
Hold Function | Manual or Automatic | |
Stability Conditions | Low or High | |
Calibration Due | 0 to 31 days | |
Power Off | Manual or Automatic (10, 20, 30 minutes) | |
Reset Function | Yes | |
Memory | Stores up to 500 data sets | |
Output | USB Communication Interface | |
Connector | BNC, 6-pin Mini Plug | |
Power Requirements | 3×1.5V "AA" Batteries | |
Battery Life | Approximately 150 hours (Turn off the backlit) | |
Dimensions | 170(L)×85(W)×30(H)mm | |
Weight | 300g |
Order Code and Accessories:
Order Code: Bante900P-UK
* P11 Glass pH Electrode (Made in UK)
* K10 Conductivity Electrode (Made in UK)
* DO100 DO Probe (Made in US)
* TP-10K Temperature Probe
* pH Buffer Pouches (pH4.01, 7.00, 10.01)
* Conductivity Calibration Solutions (146uS/cm, 1413uS/cm, 12.88mS/cm)
* Carrying Case and “AA” Batteries
Order Code: Bante900P-CN
* E65-1-BNC Glass pH Electrode
* CON-1 Conductivity Electrode
* DO100 DO Probe (Made in US)
* TP-10K Temperature Probe
* pH Buffer Pouches (pH4.01, 7.00, 10.01)
* Conductivity Calibration Solutions (146uS/cm, 1413uS/cm, 12.88mS/cm)
* Carrying Case and “AA” Batteries