Bante321 Portable Fluoride Ion Meter negative ion meter ion tester Supplier's Choice
USD $410 - $650 /Set
Min.Order:1 Set
Shanghai Yanhe Instrument Equipment Co., Ltd.
Standard portable fluoride ion meter, 5 points calibration, selectable concentration unit. The meter is suitable for outdoor applications. Accuracy: 0.5% full scale.
Features:
• High performance portable fluoride ion meter is equipped with a large LCD display.
• 2 to 5 points calibration from low to high concentrations.
• Direct ion concentration readout simplifies the elaborate measurement process.
• Selectable multiple concentration units include the ppm, mg/L, mmol/L and mol/L.
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable reading for easy viewing and recording.
• Manual temperature calibration improves the measurement accuracy of meter.
• Selectable temperature unit (°C or °F) meets different application requirements.
• mV measurement mode allows user to check performance of the ion selective electrode.
• Automatic electrode diagnosis shows the slope of sensor.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu can be used to set 8 parameters, including the number of calibration points,
stability condition, hold function, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
• Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use
the meter smoothly.
Model | Bante321-F | |
Ion | ||
Range | 1×10-6M~Saturation, 0.02ppm~Saturation | |
Accuracy | ±0.5% F.S | |
Resolution | 0.001, 0.01, 0.1, 1 | |
Calibration Points | 2 to 5 points | |
Calibration Solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L | |
mV | ||
Range | -1999.9~1999.9mV | |
Accuracy | ±0.2mV | |
Resolution | 0.1mV | |
Calibration Points | 1 point (Only for Relative mV mode) | |
Calibration Range | ±200mV | |
Temperature | ||
Range | 0~105°C, 32~221°F | |
Accuracy | ±0.5°C, ±0.9°F | |
Resolution | 0.1°C | |
Calibration Range | Measured value ±10°C | |
Temperature Units | °C or °F | |
Others | ||
Temperature Compensation | 0~100°C, 32~212°F | |
Compensation Mode | Manual or Automatic | |
Hold Function | Manual or Automatic | |
Stability Conditions | Low or High | |
Calibration Due | 0 to 31 days | |
Power Off | Manual or Automatic (10, 20, 30 minutes) | |
Reset Function | Yes | |
Memory | Stores up to 500 data sets | |
Output | USB Communication Interface | |
Connector | BNC | |
Power Requirements | 3×1.5V "AA" Batteries | |
Battery Life | Approximately 150 hours (Turn off the backlit) | |
Dimensions | 170(L)×85(W)×30(H)mm | |
Weight | 300g |