Traction Bed for cervical and lumbar vertebra treatment
Negotiable /Set
Min.Order:1 Set
Anyang Xiangyu Medical Equipment Co., Ltd.
Technological parameters:
Power voltage: AC220V±22V; 50Hz±1Hz.
Rated input power: ≤600w.
Total traction time: continuously adjustable within 0~99min.
Intermittent traction time: continuously adjustable within 0~9min.
Continuous traction time: continuously adjustable within 0~9min.
Angulated angle movement range: continuously adjustable within -30°~+10°.
Rotation movement range: 25°on each side (continuously adjustable).
Yawing movement range: 10°on each side (continuously adjustable).
Weight: 150Kg.
Lumbar vertebra
Slow traction distance: 0~150mm.
Slow traction force: continuously adjustable within 0~999N.
Speedy traction is determined by traction distance; traction force≥3000N.
Speedy traction distance: 0~70mm.
Speedy traction speed: ≤1s.
Waist thermal therapy temperature: ≤55°C.
Cervical vertebra
Traction force: continuously adjustable within 0~200N.
Cervical vertebra traction distance: 0~300mm.
Technological advantages:
1. Lumbar vertebra speedy traction (Both the distance and the force are protected).
2. Lumbar vertebra slow traction.
3. It can rotate synchronously in speedy traction and its speed can be increased gradually. When the patient’s waist muscle relaxes, speedy rotation and side pull can be carried out.
4.In the process of speedy traction, traction can either go before rotation or go hand in hand with it. Treat in a dialectical way to ensure safety.
5. In upward traction of the chest, speedy level rotation to the left side or right side can be carried out to rectify scoliosis.
6. The high speed index in speedy traction reflects the concept of speediness. The explosive force is as high as 3000N~6000N.
7. The Lenovo computer system controlling the device is stable and reliable as most of its important accessories are imported from abroad.
8. The reset journey following the traction is stable and controllable, adding to the effectiveness of treatment.
9. The treatment effect and application range of the device is strengthened by the integration of lumbar vertebra speedy and slow traction, complex traction, and cervical traction.
10. Spin the traction bed’s rotation board around the center of the patient’s lumbar in treatment to make the rotation center of the bed overlap the spine center of the body; to make the rotation center of the board near buttocks and waist agree with the lumbar vertebra center as much as possible so that the patient feels no shear force on lumbar vertebra in treatment, avoiding additional injury.
11. Double centers overlapped spinal column traction treatment is an automatically controlled system integrating machinery, electric, and computer technologies. It makes use of closed-loop control with Windows as operating deck, editing program software with (C++)language. PCL bus-mastering makes the whole system more stable, safe, and reliable.
12. It has rotation traction patent certificate.
13. The product has been approved by CE authentification.