House heating pump, hot water conbine with solar water pump
USD $500 - $1,500 /Set
Min.Order:5 Sets
Foshan Macon Cooling & Heating Energy-Saving Equipment Co., Ltd.
House heating pump, hot water conbine with solar water pump
Shell material: Spraying metal
Function: heating and hot water
Heating capacity: 3-94KW
Output water temp: 60 degree
LCD display controller or Dot matrix controller
Model | MACHRW | 010ZA | 020ZA | 030ZA | 040ZA |
Rated Output Water | L/h | 80 | 140 | 205 | 270 |
Rated Heating Capacity | kW | 3.7 | 6.5 | 9.5 | 12.5 |
BTU/h | 12700 | 22200 | 32500 | 42700 | |
Rated Input Power | kW | 1.00 | 1.80 | 2.65 | 3.45 |
Rated Input Current | A | 4.5 | 8.2 | 12.0 | 15.7 |
Rated Temp.Of Water Output | °C | 55 | 55 | 55 | 55 |
Max.Temp.Of Water Output | °C | 60 | 60 | 60 | 60 |
Power Supply | V/PH/Hz | 220/1/50 | 220/1/50 | 220/1/50 | 220/1/50 |
Noise | dB(A) | 48 | 48 | 50 | 54 |
Compressor | Rotary | Rotary | Rotary | Scroll | |
Compressor Qty | 1 | 1 | 1 | 1 | |
Fan Qty | 1 | 1 | 1 | 1 | |
Working Temp.Range | °C | -15~45 | -15~45 | -15~45 | -15~45 |
Fan Direction | Horizontal | Horizontal | Horizontal | Horizontal | |
Refrigerant Gas Type | R410a | ||||
Water Flow Volume | m3/h | 3 | 4 | 4 | 5 |
Circulating Water Out/inlet | inch | 3/4 | 3/4 | 1 | 1 |
Recyching Water Inlet | inch | / | / | 3/4 | 3/4 |
Main Unit Net Dimensions(L/M/H) | mm | 930/350/550 | 1005/360/620 | 1115/470/700 | 1115/470/945 |
Main Unit Shipping Dimensions(L/M/H) | mm | 1035/395/585 | 1095/405/650 | 1205/525/725 | 1205/525/975 |
Net Weight | kg | 30 | 41 | 65 | 85 |
Shipping Weight | kg | 35 | 44 | 80 | 100 |
Working principle:
Heat pump water chiller is a device which can efficiently collector and transfer heat.
Its function is to absorb the heat from the air or low-temperature water as well as to convert its own operating electric power into heat, then to transfer the heat to high-temperature environment.
Solar&water heat pump
1.The collector and regenerative volumes for the solar heat pump is much smaller than conventional systems,and making systems more compact in structure,more flexible in arrangement.
2.setting the outlet water temperature flexibly within 30~60,meeting extremely individual need
3.energy saving,high efficient,providing free hot water when sunny,when lack of sun,heat pump unit work to ensure hot water 24 hours a day when Solar radiation conditions in good circumstances,the evaporator temperature of the solar& heat pump tend to be higher than air source heat pump(heat pump unit would be turn off),which has a higher heating efficiency(COP can reach 4.5 and above),and the performance is less affected by the outdoor temperature.
4.intelligent control
5.wide range of working temperature
applied to -15~43 environmental conditions,because of solar power is everywhere ,inexhaustible,the solar & heat pump has wide range o applications,free from the local water conditions and geological conditions, and friendly to the environment.
6.all weather
Regardless of the sunny,cloudy,rainy,evening, provide endless hot water.