Factory Manufacture SD-100C 36~72V input 100W DC-DC converter
USD $15.25 - $17.35 /Piece
Min.Order:1 Piece
Yueqing Leyu Electric Automation Co., Ltd.
Factory Manufacture CE RoHS High Standard 100W dc converters 12v 24v
CE 100W 24VDC Input 12VDC Output SD-100B-12 12V DC-DC Converter Quality Choice
Factory Manufacture 100W dc dc converter CE approved dc 36v to 12v converter
100w dc dc converter single output factory outlet 12v output step down converter
SD-200W CE CCC 2 years warranty 5v 12v 24v 48v dc to dc power supply
100W DC-DC converter
Specification:
100W Single Output DC-DC Converter SD-100 series
Features:
2:1 wide input range
Protections: Short circuit / Overload / Over voltage
1500VAC I/O isolation
Built-in EMI filter, low ripple noise
100% full load burn-in test
Fixed switching frequency at 83 KHz
24V and 48V input voltage design refer to LVD
Low cost High reliability
2 years warranty
SPECIFICATION | ||||||||||||||||
OUTPUT |
| |||||||||||||||
Model | SD-100A-5 | SD-100C-5 | SD-100D-5 | SD-100B-12 | SD-100C-12 | SD-100D-12 | SD-100B-24 | SD-100C-24 | SD-100D-24 | SD-100B-48 | SD-100C-48 | SD-100D-48 | ||||
DC Voltage | 5V | 12V | 24V | 48V | ||||||||||||
Rated Current | 20A | 8.5A | 4.2A | 2.1A | ||||||||||||
Current Range | 0~20A | 0~8.5A | 0-4.2A | 0-2.1A | ||||||||||||
Rated Power | 100W | 102W | 100.8W | 100.8W | ||||||||||||
Ripple & Noise | 100mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | ||||||||||||
Voltage Adj. Range | 4.5~5.5VDC | 11~16VDC | 23~30VDC | 43.2-52.8VDC | ||||||||||||
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ||||||||||||
Line Regulation | ±0.5% | ±0.3% | ±0.2% | ±0.2% | ||||||||||||
Load Regulation | ±0.5% | ±0.3% | ±0.2% | ±0.2% | ||||||||||||
Setup, Rise Time | 2s,50ms(only D mode) at full load | |||||||||||||||
Hold Up Time | 20ms(only D mode) at full load | |||||||||||||||
|
| |||||||||||||||
INPUT |
| |||||||||||||||
Voltage Range | A:9.2~18VDC B:19~36VDC C:36~72VDC D:72~144VDC or 85~132VAC | |||||||||||||||
Efficiency | 74% | 75% | 76% | 75% | 77% | 80% | 78% | 81% | 83% | 78% | 81% | 83% | ||||
DC Current | 4.8A/24V | 2.4A/48V | 1.8A/96V | 4.8A/24V | 2.4A/48V | 1.8A/96V | 4.8A/24V | 2.4A/48V | 1.8A/96V | 4.8A/24V | 2.4A/48V | 1.8A/96V | ||||
Inrush Current | D:18A/96VDC | |||||||||||||||
Leakage Current | <0.75mA/120VAC(SD-100D) | |||||||||||||||
|
| |||||||||||||||
PROTECTION |
| |||||||||||||||
Over Load | 105~135% rated output power | |||||||||||||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | ||||||||||||||||
Over Voltage | 5.75~6.75V/10%load | 16.8~20V/10%load | 31.5~37.5V/10%load | 60.2-79.2/10%load | ||||||||||||
Protection type:Hiccup mode,recovers automatically after fault condition is removed | ||||||||||||||||
|
| |||||||||||||||
ENVIRONMENT |
| |||||||||||||||
Working Temp. | -10~+60℃ (Refer to “Derating Curve”) | |||||||||||||||
Working Humidity | 20~90%RH non-condensing | |||||||||||||||
Storage Temp.,Humidity | -20~+85℃,10~95%RH | |||||||||||||||
Temp.Coefficient | ±0.03%/℃ (0~50℃) | |||||||||||||||
Vibration | 10~500Hz,2G 10min./1cycle,60min.each along X, Y, Z axes | |||||||||||||||
|
| |||||||||||||||
SAFETY &EMC |
| |||||||||||||||
Safety Standards | IEC60950-1CB approved by TUV(for D type only) | |||||||||||||||
Withstand Voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||||||||||
Isolation Resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC /25℃ /70%RH | |||||||||||||||
EMC Emission | Compliance to EN55022(CISPR22) Class B | |||||||||||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,6,8,light industry level,criteria A | |||||||||||||||
|
| |||||||||||||||
OTHERS |
| |||||||||||||||
Dimension | 199*98*38mm(L*W*H) | |||||||||||||||
Weight | 0.55Kg | |||||||||||||||
Packing | 30pcs/16.5Kg | |||||||||||||||
|
| |||||||||||||||
NOTE |
| |||||||||||||||
1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
Detailed photos :