Product Details

R134a DC 12/24/48V Refrigerating Compressor

Place of Origin Guangdong, China
Brand Name Greatcool
Model Number ZH1524A(Y)1
Type Refrigeration Compressor
Application Other, Refrigeration Parts, from LBP to HBP

Product Features

The micro DC frequency conversion compressor that we research and develop, which is the smallest, lightest, 

and energy efficiency is the highest in China domestic market. 

Ideal for a variety of demands and application fields of narrow space, high temperature conditions, portable mobile.

 

Main Features:

 

1.Subminiature volume: 54.7 mm diameters, 101 mm height, less than cans. 

 

2.Ultra-light weight: total weight is only 700 grams.

 

3.Adjustable speed of direct current: DC 12V, DC 24V, we exclusively uses 180-degree sine wave controller, which with adjustable speed from 1800RPM to 6500RPM. High efficiency, low noise.

 

4.Low vibration: special designed device for vibration reduction.

 

5.Power supply: batteries, vehicular power, solar, etc.

 

6.Application: apply to evaporating temperature from LBP to HBP.

 

7.High temperature working condition: can work in 55 degrees.

 

 

 

Application:

  1. Telecom base station room, mobile base station;
  2. Medical laser cosmetic, medical radio frequency machine with cold water machine, etc;
  3. Industrial dehumidifier, domestic dehumidifier;
  4. Military, fire protection, etc;
  5. Other applications, car refrigerator, the cooling of electronic equipment in harsh environment, instead of semiconductor cooling, as well as other miniature refrigeration systems, etc.

 

Basic Parameters:

Displacement

1.5cm³/rev

1.9cm³/rev

The power supply

DC 12V

DC 24V

DC 48V

DC 12V

DC 24V

DC 48V

Model

ZH1512A

ZH1524A1

ZH1548A

ZH2012A

ZH2024A

ZH2048A

Refrigerant

R134a

Lubricating oil·amount (ml)

POE 68 ·30ml

Total mass(including oil)

700g

Motor type

Brushless DC Motor

 

R134a DC 12/24/48V Refrigerating Compressor

 

R134a DC 12/24/48V Refrigerating Compressor

 

R134a DC 12/24/48V Refrigerating Compressor

 

R134a DC 12/24/48V Refrigerating Compressor

 

R134a DC 12/24/48V Refrigerating Compressor

 

R134a DC 12/24/48V Refrigerating Compressor

 

Remarks:

  1. Basic test conditions:Inhale/superheat temperature----- 18 °C (evaporation temperature 20 °C, the degree of superheat 5 k)

    Too cold temperature-------------6K

    The environment temperature ------------- 35°C

  2. This whole performance value of the company use our company compressor performance test rig, dedicated controller test;

  3. This all performance values are for reference only, actual product performance, please will be subject to relevant specifications of the products;

 

1.The compressor using conditions

project

Standard conditions

Overload condition

Exhaust pressure(MPa)

below 1.8

above 2.2

Compression ratio

below 8

Motor Volume line temperature(°C)

below 100

below 125

The exhaust temperature(°C)

below 100

below 115

ΔT=(Temperature at the bottom of the compressor-The condenser temperature in the middle)

During continuous operation:More than 5 K,
Starting and control the runtime: 0 K above

Running interval

More than 5 min 1 cycle
(ON more than 2 min, OFF more than 2 min)

Angle of tilt allows

The system is installed within 5 °

RefrigerantSeal in quantity

R134a    Max 120g

Speed adjustment

The speed rate of change: within 60 r/s
Control the runtime: within 10 r/s     
Starting: when near 60 r/s keep running more than 1 min                  

Pressure when starting 

High side and low side pressure balance

Turning direction

Beware of the reverse connection failure

Interphase voltage balance

Less than 2%

 

2.Other considerations
1.Prevent the compressor from falling and being impacted during handling and operation.

2.Ban exerting local pressure on exhaust pipe and seal terminals.

3.Compressor shall be stored in the little dust and low humidity environment.

4.Don't be placed for long period but install and use ASAP, after pulling out the suction and exhaust pipes of the compressor.

5.Prohibit running the compressor in the air.

6.It can not directly inject the refrigerate into the compressor, it'd beeter inject from the end of the condenser before the refrigerant to be sealed.

7.It is recommended to use the special compressor driven controller and other accessories of our company.

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now