ISO BMW modular homes
Negotiable /Unit
Min.Order:1 Unit
Shanghai CILC Modular House Co., Ltd.
40ft prefabricated container house
1.1 Dimensions (mm) and weights (kg):
Type | External | Internal | Weight (approx. specifications) | ||||||
Length | Width | Height | Length | Width | Height | BM | BU | SU | |
10’ | 2989 | 2435 | 2591 2700 2896 | 2795 | 2240 | 2275 2383 2580 | 1150 1350
| 1200 1200 | 1450 1550 |
16’ | 4885 | 2435 | 2591 2700 2896 | 4690 | 2240 | 2275 2383 2580 | 1600 1750 | 1550 1600 | |
20’ | 6055 | 2435 | 2591 2700 2896 | 5860 | 2240 | 2275 2383 2580 | 1950 2000 | 1750 1800 | 2450 2550 |
24’ | 7335 | 2435 | 2591 2700 2896 | 7140 | 2240 | 2275 2383 2580 | 2300 2400 | 2050 2150 | |
30’ | 9120 | 2435 | 2591 2700 2896 | 8925 | 2240 | 2275 2383 2580 | 2550 2800 | 2450 2500 |
1.2 Insulation
Component | Insulation type | Thickness | U-value (W/m²K)* |
Roof | |||
CN-31 | MW | 100 | 0.359 |
CN-31 | MW | 140 | 0.233 |
CN-11 | PU | 100 | 0.198 |
CN-11 | PU | 140 | 0.145 |
Wall element | |||
CN-31 | MW | 60 | 0.574 |
CN-31 | MW | 100 | 0.348 |
CN-11 | PU | 60 | 0.380 |
CN-11 | PU | 110 | 0.210 |
Floor | |||
CN-31 | MW | 80 | 0.548 |
CN-31 CN-11 | EPS | 80 | 0.364 |
CN-11 | PU | 80 | 0.196 |
Window | |||
standard insulated window 1/2 | 4/16/4 mm | 2.90 | |
window insulation with gas filling | 4/16/4 mm | 1.10 | |
External door | |||
polystyrene | 40 mm | 1.4 |
* The U-values apply to the stated insulation thickness in the space between the timber frames in a half-timbered
construction (within the panel).
Material Data
Further insulation options upon request!
1.3 Load bearing capacity
floor load: ground floor: max. load capacity 2.0 kN/m² (200 kg/m²)
top floors: max. load capacity 1.5 kN/m² (150 kg/m²)
snow load: max. load capacity 1.0 kN/m² (100 kg/m²)
(equates to a typical snow load on the ground of sk1.25 kN/m² (125 kg/m²)
according to EN1991-1-3 with the national application document B1991-1-3)
wind load: 90 km/h [25 m/s] - terrain category III
When wind speeds are higher than 90 km/h (25m/s) additional safety
measures on the cabins need to be carried out (anchoring, screwing).
measurements are to be calculated by approved specialists taking into
Such measurements are to be calculated by approved specialists taking into consideration local standards and conditions.
All calculations were undertaken according to the European standards of ENV. Higher load capacity upon request
1.4 Sound insulation 33 - 44 dB
1.5 Certification
LPCB certificate for CN31
ISO9001:2000
ISO14001:2004
American Bureau of Shipping
1.6 Our projects and experience