Specifications
Certificate:ISO9001
Rugged-double double stage
Pressure range:20~80Mpa
Five pressure ratios available
- PST 60 Air driven gas boosters are high pressure reciprocating pumps used for gases boosting,driven of compressed shop air.PST Series boosters are double stage, double acting.They are capable of gas boosting from very low to super high pressure.Gas inlet pressure as low as 0.2bar (2.9psi.).
- PST series gas boosters are suitable for the oil free compression of air and Industrial gases like Nitrogen, Helium as well as flammable and risk gases like hydrogen,oxygen and natural gas.Air drive pressure from 1bar(14.5psi.)to 8bar(116psi.).Provide for operating pressures up to 80Mpa.
Key features
- Double action for effective operation.Double stage for high pressure available
- No electricity required. Safe operation, ex-proof
- More appropriate ratios for meeting higher flowrates and faster fill times
- No airline lubricator required
- Hydrocarbon free-seperation between air drive and gas booster sections
- Suitable for most gases
- Built-in cooling
- High quality seals, long life service available
- All components in contact with the gas are made of aluminium or resp. stainless steel
- Wide range of models. There are five models for your option
- Standard and custom systems available
- Reliable,easy operation and maintenance
Applications
- Mining,fire&safety
- Aircraft ground support
- Automotive air bag vessel filling
- Power generation
- Injection moulding
- Accumulator charging
- Supply for isolating gas systems
- Gas proof testing
- Hydrostatic and Burst Pressure testing for valves,pipes and tubing,pressure vessels and air craft components,etc.
- Safety valve adjusting
Technical parameters
Type | Pressure ratio | Min. gas Inlet pressure PA (bar) | Min. gas outlet Pressure PA (bar) | Max.gas oulet pressure PB (bar) | Formula to calculate gas oulet pressure PB | Connection: Gas Drive/ Gas Inlet / Gas outlet | Max. flow at air drive pressure of 6 bar(L/min) |
PST25 | 25:1 | 0.2 | 10 | 200 | 25XPL+3.5PA | G1/2 / ZG1/4/ ZG1/4 | 83 (at PAof 8 ar ) |
PST40 | 40:1 | 0.2 | 10 | 320 | 40XPL+ 6PA | G1/2 / ZG1/4/ ZG1/4 | 75(at PA of 8 bar ) |
PST60 | 60:1 | 0.2 | 10 | 480 | 60XPL+6PA | G1/2 / ZG1/4/ ZG1/4 | 51 (at PA of 8 bar ) |
STT100 | 100:1 | 0.2 | 10 | 800 | 100XPL+10PA | G1/2 / ZG1/4/ ZG1/4 | 38 (at PA of 8 bar ) |
Note: PL: air drive pressure PA: gas inlet pressure PB: gas outlet pressure
Please consult us for printable dimensional drawings and performance charts for STT Series boosters sized to your specific application parameters.