48 Energy Meter Positions Single Phase Energy Meter test bench
Negotiable /Set
Min.Order:1 Set
SMS Electric Co., Ltd. Zhengzhou
Single Phase Energy Meter test bench with 24 Energy Meter Positions
Single Phase Energy Meter test bench with 48 Energy Meter Positions
Three Phase Energy Meter Test with 24 Energy Meter Positions
Three Phase Energy Meter Test Bench with 3 Energy Meter Positions
Single phase energy meter test bench with 60 Energy Meter Positions
Features
1. new type aluminum alloy case special machine case, science and technology morden appearance;
2. matching number multifunctional standard energy meter ,high accuracy well long-distance stability;
3. conrolled with special keyboard;
4. controlled with PC ,software can manual or full automatic testing meter;
5. PC can warmup in advance , when warmup scanning head can auto capture spot,judge electric pulse connection,
6. could test same specification different constant meter at same time;
7. according testing regulation requirement , full auto testing single phase no-load,starting ,basic error,standard deviation;
8. test project and measure project can be edited,copied,deleted,backup and set password to protect;
9. could auto capture mechanism spot to decrease starting,no-load testing time ;
10. empty meter current can auto short connect,have no sue for outside connection;
11. set output voltage short circuit,current opend alarming to protect;
12. according regulation requirement auto account starting testing,no-load testing time ans setted output voltage ,current , and auto judge testing result .
13. reading test have three modes to test energy meter constant:pulse ,time,start/stop energy;
14. pulse collection port can compatible scanning pulse,different level of electric pulse;
15. auto record and amend data,judge testing result ,data saving ,database auto backup ;
16. support more testing record,report ,certificate print , print format multiplicity;
17. support bar code input energy meter asset information ,auto analysis bar code information, support user-defined bar code information;
18. support error graph, user system administrate setting ,error upperlimit and lower limit setting , more testing project setting;
19. break off can continue , allow hang a meter testing , pause and continue currently testing;
20. software have sell system MIS port , testing data can auto upload to sell system;
21. support MISnet database or server reading meter asset information,download testing project,working menu ;
22. computer software support long-distance maintenance
Index
item | Class 0.05 | Class 0.1 | |
Equipment accuracy class | 0.05 for active | 0.1 for active | |
Standard meter accuracy class | 0.02(0.05) | 0.05 | |
Measure repeatio (cosφ=1.0) | 0.005 | 0.007 | |
Current range | 0.01A, 0.5A1.0A2 .5A 5A10A20A50A100A | ||
Voltage range | 220V | ||
Output power | voltage | 600VA | |
Current | 960VA | ||
Voltage adjusting | Adjusting range | 0~120% | |
Adjusting resolution | 10%1%0.1%0.01% | ||
Current adjusting | Adjusting range | 0~120% | |
Adjusting resolution | 10%1%0.1%0.01% | ||
Phase adjusting | Adjusting range | 0.00°~359.9° | |
Adjusting resolution | 10°1°0.1°0.01° | ||
Frequency adjusting | Adjusting range | 45.00~65.00Hz | |
Adjusting resolution | 10Hz1Hz0.1Hz | ||
Waveform distortion | <1.0% | ||
Power stability | <0.05% | ||
Display Accuracy class | Voltage | ±0.2% | ±0.2% |
Current | ±0.5% | ±0.5% | |
power | ±0.5% | ±0.5% | |
frequency | ±0.2% | ±0.2% | |
phase | <0.2° | <0.2° | |
Working power | 220V±15%,50/60Hz | ||
Dimension | Meter rack |
| |