DZ601-24 Single Phase Energy Meter Test Bench
Negotiable /Set
Min.Order:1 Set
SMS Electric Co., Ltd. Zhengzhou
DZ601-24 Single Phase Energy Meter Test Bench
Main functions and features:
1- Applied to test all kinds of single-phase energy meter
2- simultaneous measurements for energy meters with the same spec but different meter constant or different accuracy class.
3- operation mode:SMS special keyboard and SMS PC software control
4- display mode: error indicator on each meter position / PC monitor
5- support below test items, include:
no-load test
start test
basis errors test
meter constant test
voltage influence test
meter reverse turn test
energy counting test
6- Auto-turnning up of photoelectrical scanning head
7- full-automatic current/voltage measuring range switching
8- auto-alarming protection against output voltage short circuit and current open circuit
9- auto capturing the black dot on the rotor before starting test and no-load test
10- Harmonic setting
11- Waveform display
12- keyboard current load testing point setting in common use: Imax4Ib2Ib1.5Ib1.0Ib0.5Ib0.2Ib0.1Ib, 0.05Ib
13- keyboard voltage load testing point setting in common use: 1.2(1.15)Un1.1Un1.0Un0.8Un
14- keyboard phasor testing point setting in common use:0.5C,0.5L, 1, 0.8C,0.8L
15- programmable Voltage/ current/ frequency and phase angle
16- support bar code input, error curve, error limit setting , multi-mode calibration plans setting and equipment authoriy by PC software
17- support data processing and verification certificate printting with customized table format
18- communication test. Specially equiped with RS485 communicaiton box for the impulse receiving and switching in order to test electronic multi-function meter (optional function)
19- able to measure and save the circumstance temperature and relative humidity (optional function)
20- forced device warmingup function can gurantee the accuracy and normal running.(optional)
Technical Index:
1)Accuracy classes: 0.05,0.1,0.2.
2)Model: DZ601-24( meter position can be customized)
3)Equipped with 0.05 class three phase reference standard meter
4)The maximum output current: 120A; Ranges: 0.1A, 0.5A, 1.0A, 2.5A, 5A, 10A, 20A,
50A, 100A
5)Voltage is divided into four ranges: 57.7V, 100V, 220V, 380V
6)Voltage output power: 280VA per phase, current power: 450VA per phase
7)For each range of current and voltage, 0~120% of the range value can be
continually adjusted, the resolution is better than 0.01% of range value
8)Accuracy of Indication Meter:
Voltage meter: class 0.5, Current meter: class 0.5,
Frequency meter: class0.3 phase meter: class 0.3
9)Phase scope 0~359.9 degrees, adjusted resolution is 0.1 degree
10)Testing points of power factor: 0.5C, 0.8C, 1.0, 0.8L, 0.5L
11)Range of frequency is from 45.00 to 65.00Hz, adjusted resolution is 0.01Hz
12)Shall set and measure 2-21 times harmonic and measure the distortion
13)Output power stability: 0.05%(PF=1.100Sec)
14)Wave distortion of outputting: < 1%
15)Voltage supply: AC220V+/-10% 50Hz