UV Weathering Chamber UV Xenon Test Chamber
USD $2,000 - $6,000 /Set
Min.Order:1 Set
Guangdong Yuelian Instruments Co., Ltd.
Purpose:
UV Weathering Chamber UV Xenon Test Chamber adopts fluoresvent UV lamps as light sources to perform
accelerated weathering test on materials by means of simulating ultraviolet radiation and condensation of
nature’ssunshine,so as to know about the weather ability of materials This machine is apply to nonmetal
material, organic material (like paint coating. rubber, plastic and products made in these materials).
Standards:
GB/T14522-93,GB/T16422.3-1997,GB/T16585-96 etc.
Technical Parameters:
1. Temp. Range | RT+10°C~70°C |
2. Humidity Range | ≥95%R.H |
3. Temp. Accuracy | ≤±0.5°C |
4. Temp. Uniformity | ≤±2°C |
5. Humidity Accuracy | ≤±2% |
6. Humidity Uniformity | ≤±2% |
7. Blackboard Temp. | 40°C~65°C |
8. Distance Between Lamps | 35mm |
9. Distance Between Lamp and Specimen | 50mm |
10. Lamp Power | 40W |
11. UV Wavelength | 290nm~400nm(Specify when ordering) |
12. Simulation Condensation | Condensation system time is adjustable |
13. UV exposure, simulation condensation time range | 0~99 hour |
14. Support Specimen | 150×75(mm) |
15. Specimen Quantity | Approx 40pcs |
16. Testing Time | 0~9999H, adjustable |
17. Irradiance Range | ≤50w/m². |
18. Working Chamber Dimension | D×W×H450×1170×500mm |
Light Source:
1. Using 8pcs UV fluorescent lamps with 40W power rating as light source. UV fluorescent tubes are distributed on both sides of the machine, each side has 4pcs. It has UVA-340 and UVB-313 optional for customers’
configuration. (Option one type)
2. UVA-340 lamp luminescence spectra energy is mainly concentrated in the 340nmof wavelength.
3. UVB-313 lamp luminescence spectra is mainly concentrated near the 313nm of wavelength.
4.Due to fluorescent light energy output will gradually decay over time, in order to reduce the test effect because of light energy attenuation, when in every 1/4 of the fluorescent lifetime of eight lamps in the chamber, a new lamp will replace an old lamp, thus UV light source is always formed by new lamp and old lamp, to get a constant output of light energy.
5. the effective useful life of the lamp is about 500 hours (imported one is about 1600~1800 hours).
Standard: GB/T14522-93GB/T16422.3-1997GB/T16585-96 and other current UV aging test standards.