415VAC 400kW manual control resistive dummy load bank for generator testing
USD $5,980 - $15,000 /Set
Min.Order:1 Set
Shenzhen JMHING Electronic Technology Co., Ltd.
AC LOAD BANKS
Purely resistive load bank is the most common type of load bank, and it proves equivalent loading of both generator and prime mover. That is, for each kilowatt of load applied to the generator by the load bank, an equal amount of electrical energy converts to heat by power resistors, in a general way, this heat must be dissipated from the load bank by air forced means or other convection.
The JMHing’s resistors are made by high quality finned tubular heating elements, they are of the type where the surface area is enlarged by a strip in order to heat gases. At high power the surface temperature is small and the heating element is short. Meanwhile, Load elements are cooled usually via Fan Forced Air, blower power is typically provided by an outside source. Selected load banks are available with blower power derived from the power source under test.
JMHing’s AC resistive load banks can be further divided into these categories:
AC resistive load banks | ||||||
Models | 230VAC-6kW-R | 480VAC-30kW-R | 480VAC-60kW-R | 480VAC-100kW-R | 480VAC-200kW-R | 480VAC-400kW-R |
Capacity | 1-6kW | 10-30kW | 30-60kW | 60-100kW | 100-200kW | 200-400kW |
or units can be designated at any capacity made to order | ||||||
Rated voltage | 230VAC | 480VAC | ||||
or units can be designated at any voltage made to order | ||||||
Rated current | 1 phase: 26A | 1 phase: 36A 3 phases: 108A | 1 phase: 72A 3 phases: 216A | 1 phase: 120A 3 phases: 361A | 1 phase: 240A 3 phases: 721A | 1 phase: 481A 3 phases: 1443A |
Frequency | 50Hz/60Hz | |||||
PF | PF=1.0 | |||||
Minimum load step | 100W | 100W | 100W | 1kW | 1kW | 1kW |
or units can be designated at any minimum load step | ||||||
Display | Voltage, Current, Frequency, Power and PF displayed by digital meter | |||||
Protection | Overheating alarm, Short circuit protection, Overheating protection, Emergency stop button, All protection can be configured optionally | |||||
Control mode | Manual control by MCBs or button switches or toggle switches | |||||
Air flow | horizontal | vertical | horizontal | horizontal | horizontal | horizontal |
Force-air cooling | ||||||
Dimensions | 49*60*21(cm) | 50*67*116(cm) | 51*97*110(cm) | 81*97*155(cm) | 80*120*161(cm) | 80*180*150(cm) |
Options | Handle panel or PC remote control selectable | |||||
Ambientparameters | Maintains maximum capacity in ambient conditions up to 55° C, and 95% humidity |
400kW 415VAC manual control resistive dummy load bank specifications
Product name | 415VAC-400kW-R Load Bank |
Model number | 415VAC-400kW-R |
Brief | 415VAC-400kW-R load bank is designed as requested parameters. It can compose any power capacity that you want in 400kW based min load step 10kW at 415VAC, 3 phase, 50Hz working condition. PC remote control software and handheld control panel are included.
After futher discussion, 400kW load bank can supply any load step solution with 400kW and any designated voltage to meet all your testing requirements. |
Capacity | Maximum power 400kW resistive load supply at 415VAC |
Design voltage | 3 phase, 415VAC |
Power range | 50Hz |
Control system | local manual control by switches fixed in the enclosure |
Power factor | 1 |
Load segment | Resistive loading at 415VAC A phase Resistive load: 2kW/5kW/10kW/10kW/20kW/20kW/20kW/50kW total 137kW B phase Resistive load: 2kW/5kW/10kW/10kW/20kW/20kW/20kW/50kW total 137kW C phase Resistive load: 2kW/5kW/10kW/10kW/20kW/20kW/20kW/50kW total 137kW or units can be designed for a three phase equilibrium procedure made to order |
Minimum load step | 2kW |
Cooling | Force-air cooling by axial-flow fans |
Protection | (1)Short circuit protection (2)Overheating alarm (3)Emergency stop button (4)Fuse protectors |
Enclosures | Steel container enclosure |
Insulation class | Class F |
connectors | A, B, C, N |
Dimensions | Height: 1800mm Width: 900mm Length: 1500mm |
Ambient parameters | Maintains maximum capacity in ambient conditions up to 55° C, and 95% humidity |
Transportation | Robust swivel wheels and housed in a sheet steel enclosure |
The load banks will have all the necessary factory tests and site tests before delivery, e.g. 1kV insulation resistance test, 2.5 kV high-voltage dielectric strength test, temperature rise test at full load, functional tests,etc. |