New Co2 Laser 1500mj Tattoo Removal Mv12 Machine 800mj
Negotiable /Piece
Min.Order:1 Piece
Sunny Optoelectronic Technology Co., Ltd.
Advantage:
1.touch screen
2.high power
3.two main board(energy stable control)
light guidance
5.Separable connector
6.Powerful cooling system(guarantee the long time working)
manufatuer Dermatology CO2 Laser treat every kinds problems to skin hot selling high power with ultra pulse
1. Treatment principle
The CO2 surgical laser system –CL20(15W) with CE and ISO certificates. It adopts sealed off CO2which wavelength is 10600nm, the characteristic are a good direction and high energy density.
If the laser transmitted through focus lens, the high temperature produced by the focus spot can gasify, cutting and cauterization the target organ .If the laser not transmitted through the focus lens, the energy density is low, then it can be used for freezing.If the laser transmitted through beam expander, the instrument can be used in irradiating physical therapy.
2. Construction Performance
2.1 Laser tube
The laser make of glass tube filled with CO2 air. The back end sticks the whole reflection mirror slice and the front end sticks the exportation window mirror slice which consists of laser cavity resonator. The electrode is installed on the side.
When the electrode of lasers connect with high voltage and electric current, the CO2 gas is motivated so as to produce laser and be sent out from the exportation window of the laser. There are cooling pipe line, cooling with water inside of its.
Q swithced nd yag laser working Principle:
The energy of Q-switched ND:YAG laser can be absorbed by the blue and black melanin.The melanin will be fragmented so small that they can be metabolized by the lymphatic system or egested out of the body. Thus the tattoo or other pigmentations will be removed without damage to normal tissue.The treatment is safe and convenient without downtime and side effects.
2.2 The guiding light joint arm
It consists of even joints and a guiding light tube. There are laser reflector slices in the joints. Laser beam through focus lens outputs in the interval after reflecting for many times. The outlet can be assembled with focused lens, all kinds of operation head- knife and expanding beam lens.
Application of head-knife,
Focus Lens of laser articulated arm F = focal length of 100mm (1F).It
(F=100mm) can be used with cutting head-knife (1F) or ENT head-knife, please
make sure the output end is away from the skin around 5mm.
Other head- knife’s length over 100mm (as:1.3 F, 1.6 F, 2 F), far away from the focus, more big spot, the density will be lower, so the heads can be used for solidification.(offering 5 pieces headknife,5 of them are for backup).
2.3 Power supply and Control parts
It is combined with switching power supply and computer control parts. Adjusting the current of switching power supply can control the output power of the laser. Control parts are made up of the micro-computer control panel, data collect board, liquid crystal display and touch panel
2.4 Cooling circle system
The large amount of heat will happen when the instrument works. We use the inner circle system to cool off. The pure water is in the tank, which is sent by pump to the laser pipes and reflows to the tank through flow controller.
2.5 Instruction laser (DIODE),
When the status is STA-BY, press the key “A.BEAM” to select if use the red indicate light or not. Press the key Continuum to select the output status of instruction laser.
2.6 Instant stop button
Press this button to cut off the power and stop the laser output when the foot switch is out of work or other problems happen. Turn the button clockwise to spring out it so as to restore original position when the problems settled.
2.7Control switch(foot step switch)
The foot step switch of the instrument is a kind of drop– proof type suiting for the common laser clinic. The water- proof foot step switch is suit in the operating room.
2.8 Protecting cooling water from error
If the circle cooling water appears error, the laser tube will be damaged. So the instrument lacks water, or water temperature is over 45 °C, the computer will cut off the power supply and produce the alarm sound automatically.
2.9 Safety door link lock
To assure safety on operating, the door must be closed. Then connect the switch with “the door link socket" of the instrument. If the door of the operation room is opened when operating, the instrument will stop transmitting laser.
Feature and Benefits:
1) Innovative in laser technology, strict in technical detection, precise in manufacture.
2) Special designed cooling system ensures constantly working.
3) New fashionable outlook design.
4) Portable and aseismatic, convenient for transportation.
5) No injury to normal tissue.
6) Remove pigmentation without side effects or scar.
7) Accurate infrared indication light makes the spot position more accurately and increases the utilization of light point
3. Application
The equipment is featured by reasonable construction, stable performance, safety, and reliability.
The CO2 laser therapy apparatus model is suitable for used extensively in such departments as dermatological, ENT, gynecological and general surgical for cautery and vaporization treatment. This machine is well suited to usage by different levels of hospitals and medical centers. The detailed using scope is as following,
3.1.
3.2. E.N.T: all kinds of rhinitises, nose polyps, pharyngitises, oral hemangiomas.
3.3.
3.4.
3.5.
3.6.
Technical Paramters
Color computer screen | 8 inch touch screen | |
Laser wavelength | 10600nm | |
Power to tissue | >15W (C.W) | |
Focal spot diameter | <0.5mm | |
operation mode | CW Repeat pulsesuper pulse | |
articulated arm | 7-joint spring-balanced | |
Working radius | 100cm | |
Aiming beam: | Diode laser 635nm2mW (adjustable) | |
Power supply | AC220V or 110V | |
Dimension | 80(H)×× | |
Packing size | 120(D)×× | |
Gross weight | 21kg (Net weight 16Kgs ) |
Application of q swithched nd yag laser tattoo removal machine:
ND YAG laser : tattoo/eye embroidery/eyeline/freckles removal and skin whitening.
1064nm wavelength: get rid of freckles and yellow brown spot, eyebrow tattoo, failed eye line tattoo, tattoo, Birthmark and Nevus of Ota, pigmentation and age spot, nevus in black and blue, scarlet red, deep coffee and etc. deep color.
532nm wavelength: get rid of freckles, eyebrow tattoo, failed eye line tattoo, tattoo , lips line, pigment, telangiectasia in shallow red, brown and pink and etc. light color. pigment removal.
1320nm Professional for skin rejuvenation and face deep cleaning , blackhead removal, skin tightening and whitening, skin rejuvenation.